INSTALLATION
1. Refer to WARNINGS and CAUTIONS.
2. Install as close as possible to the equipment which requires filtered air.
3. Install the unit with air flowing through the body in the direction indicated

by the arrow.

4. Install a unit with the same pipe-size as the one in use. Avoid using

fittings, couplings, etc., that restrict the airflow.

5. Do not install this filter on any application where the pressure drop will

exceed 20 psi. Downstream from a quick opening valve, for example,
could cause a momentary pressure drop in excess of 20 psi.

6. The drain line connection is dependent on the type of drain that is

selected.

7. Maximum pressure rating is 150 psig (10.3 bar) for transparent plastic

bowls, and 200 psig (14 bar) for metal bowls. Temperature range is 32°F

to 125°F (0°C to 52°C) for transparent plastic bowls, and 32°F to 150°F
(0°C to 65.5°C) for metal bowls.

8. Install unit in a vertical position.

MAINTENANCE
INSPECT UNIT DAILY AND SERVICE AT LEAST EVERY 6 MONTHS
1. EACH TIME BOWL IS CLEANED OR FILTER ELEMENT REPLACED:

A. Depressurize unit.

B. Inspect seals and replace crazed, cracked, damaged or deteriorated

seals and bowls with original manufacturer's approved seals.

2. A. IF UNIT HAS A RIGID ELEMENT, replace and clean periodically by

tapping on hard surface and blowing off with air gun.

B. IF UNIT HAS OIL REMOVING CLOTH ELEMENT, replace with a new

one at least every six months, or sooner if it appears dirty or causes
excessive pressure drop (10 psi or more at rated flow).

3. Before placing unit in service be sure that the bowl and bowl guard are

reinstalled and the clamp ring is securely locked in position.

REPAIR KITS AND REPLACEMENT PARTS
Repair Kit (Type A Element) ..................................................

FRP-95-209

Bowl O-Ring Kit (Nitrile) ........................................................

GRP-95-256

Bulk Pak Kit (Type A) .............................................................

FRP-95-271

Bulk Pak Element Kit (Oil Removing) ....................................

FRP-95-272

Baffle Kit .................................................................................

FRP-95-062

Bowl Assembly Kit - No Guard ..............................................

FRP-96-315

Clamp Ring Assembly ...........................................................

GRP-96-404

Plastic Bowl Kits:
with Automatic Drain and Bowl Guard ...............................

FRP-95-775

with Flexible Drain and Bowl Guard ..................................

FRP-95-832

Metal Bowl Kits:
Metal Gauge Bowl with Petcock .......................................

GRP-95-676

with Petcock .......................................................................

FRP-95-593

with Automatic Drain and Fluorocarbon Seals .................

GRP-95-908

Drains Kits:
Flex-Drain™ .......................................................................

FRP-95-610

Automatic Drain, w/ Nitrile Seals ......................................

GRP-95-973

Automatic Drain w/ Fluorocarbon Seals ...........................

GRP-95-981

Bowl Guard ...........................................................................

GRP-95-808

ACCESSORIES
Sight Gauge Kit (for Metal Bowl) ...........................................

LRP-95-771

Bowl guards are recommended for added protection of polycarbonate bowls
where chemical attack may occasionally occur.

!

WARNING

To avoid polycarbonate bowl rupture that can cause personal injury or
property damage, do not exceed bowl pressure or temperature ratings.
Polycarbonate bowls have a 150 PSIG pressure rating and a maximum
temperature rating of 125°F.

WARNING

To avoid unpredictable system behavior that can cause personal injury
and property damage:

• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to this

product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical supplies

(when necessary) should be connected and the product tested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered by

paint, etc. If masking is not possible, contact your local representative
for replacement labels.

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE

PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED

ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY

DAMAGE.

This document and other information from The Company, its subsidiaries

and authorized distributors provide product and/or system options for further

investigation by users having technical expertise. It is important that you

analyze all aspects of your application, including consequences of any failure

and review the information concerning the product or systems in the current

product catalog. Due to the variety of operating conditions and applications for

these products or systems, the user, through its own analysis and testing, is

solely responsible for making the final selection of the products and systems

and assuring that all performance, safety and warning requirements of the

application are met.
The products described herein, including without limitation, product features,

specifications, designs, availability and pricing, are subject to change by The

Company and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR

INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE

THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

!

!

!

CAUTION

Polycarbonate bowls, being transparent and tough, are ideal for use with
Filters and Lubricators. They are suitable for use in normal industrial
environments, but should not be located in areas where they could be
subjected to direct sunlight, an impact blow, nor temperatures outside of
the rated range. As with most plastics, some chemicals can cause damage.
Polycarbonate bowls should not be exposed to chlorinated hydrocarbons,
ketones, esters and certain alcohols. They should not be used in air systems
where compressors are lubricated with fire-resistant fluids such as phosphate
ester and diester types.
Metal bowls are recommended where ambient and/or media conditions are
not compatible with polycarbonate bowls. Metal bowls resist the action of
most such solvents, but should not be used where strong acids or bases
are present or in salt laden atmospheres. Consult the factory for specific
recommendations where these conditions exist.
TO CLEAN POLYCARBONATE BOWLS USE MILD SOAP AND WATER
ONLY! DO NOT
use cleansing agents such as acetone, benzene, carbon
tetrachloride, gasoline, toluene, etc., which are damaging to this plastic.

Advertising