MAINTENANCE

1. The element operates effectively when it is saturated. The element's

useful life will end only when the resistance to flow becomes too high
or the maximum permissible pressure is reached. The element cannot
be cleaned or reused and must be replaced at the end of its useful
life.

2. IF THE UNIT HAS A MANUAL DRAIN, drain the unit once every 8

hours. IF UNIT IS EQUIPPED WITH AN AUTOMATIC MECHANICAL
DRAIN, clean the screen around the drain seat each time the element
is cleaned or replace it by removing the nut and removing the drain
assembly. Clean screen by blowing off with air blow gun.

3. When bowl becomes dirty, replace the bowl or clean by wiping with a

dry, clean cloth.

4. Before placing the unit in service, make sure that the bowl and bowl

guard are reinstalled, and securely locked in place.

REPAIR KITS AND REPLACEMENT PARTS

Bowl O-Ring Kit (Fluorocarbon) ...........................................GRP-95-009
Replacement Elements:

Type D Element Kit ..........................................................MXP-95-987
Type C Element Kit ..........................................................MTP-95-548
Type B Element Kit ..........................................................MTP-95-988

Drains:

Automatic Mechanical Drain (w/ Fluorocarbon Seals) .....GRP-95-981
Automatic Mechanical Drain ............................................GRP-95-973
Flex-Drain™ .................................................................... FRP-95-610

Transparent Plastic Bowl Assemblies:

Flex-Drain™ .................................................................... FRP-95-017
with Flex-Drain™and bowl guard..................................... FRP-95-014
with Auto. Mech. Drain and bowl guard ........................... FRP-95-015

Bowl Guard Kit .....................................................................GRP-95-013
Metal Bowl Assemblies:

with Petcock and Viton O-ring ......................................... FRP-95-178
with Auto. Mech. Drain (Fluorocarbon seals) ................... FRP-95-950

Brass Petcock Kit ................................................................ GRP-95-182
Differential Pressure Indicator ............................................. DP2-01-000

ACCESSORIES

Bracket Kit ........................................................................... GPA-95-016

O-ring

Differential

Pressure

INdicator

Gasket

Gasket

Body

Filter

Element

Type B or

Type C

Flex Drain™

(Plastic Bowls

Only)

Transparent

Bowl

Bowl

Guard

Nut

Nut

Insert

Retainer

Petcock

Metal

Bowl

O-ring

O-ring

O-ring

Bowl

INsert

O-ring

Automatic

Mechanical

Drain

Automatic

Mechanical

Drain

Plate

Body

Filter

Element

Type D

Advertising