Wilkerson M30 User Manual

Warning, Caution

Advertising
background image

Richland, MI 49083

Tel: (269) 629-5000

F

D

E

B

A

M30

C

Bowl guards are recommended for added protection of polycarbonate
bowls where chemical attack may occasionally occur.

!

WARNING

To avoid polycarbonate bowl rupture that can cause personal injury or
property damage, do not exceed bowl pressure or temperature ratings.
Polycarbonate bowls have a 150 PSIG pressure rating and a maximum
temperature rating of 125°F.

WARNING

T

o avoid unpredictable system behavior that can cause personal

injury and property damage:

• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected

to this product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure,

temperature, and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical

supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is
present, or the product does not operate properly, do not put into
use.

• Warnings and specifications on the product should not be

covered by paint, etc. If masking is not possible, contact your
local representative for replacement labels.

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF

THE

PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR

RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND

PROPERTY DAMAGE.
This document and other information from The Company, its subsidiaries

and authorized distributors provide product and/or system options for

further investigation by users having technical expertise. It is important

that you analyze all aspects of your application, including consequences of

any failure and review the information concerning the product or systems

in the current product catalog. Due to the variety of operating conditions

and applications for these products or systems, the user, through its own

analysis and testing, is solely responsible for making the final selection of

the products and systems and assuring that all performance, safety and

warning requirements of the application are met.
The products described herein, including without limitation, product

features, specifications, designs, availability and pricing, are subject to

change by The Company and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR

INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE

THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

!

!

Installation & Service Instructions
83-708-000
Coalescing Filter Model M30 with
Variations and Accessories
ISSUED: February, 2006
Supersedes: February, 2005

Doc.# 83708000, ECN# 060135, Rev. 3

INSTALLATION

1. Refer to Warnings and Cautions.
2. Purge downstream air line of oil.
3. Install as close as possible to where regulated air is being used.
4. Install the unit with the air flowing in the direction indicated by the

arrow on the body.

5. A drain line with 3/8" or 10mm ID flexible tube connection may be

attached to drain port if desired.

6. Maximum pressure rating is 150 psig (10.3 bar). Temperature range is

32°F to 125°F (0°C to 52°C) for transparent plastic bowls, and 32°F to
150°F (0°C to 65.5°C) for metal bowls.

TYPICAL INSTALLATION (not to scale)

A. PREFILTER - It is recommended that a 5-micron-rated prefilter be

installed upstream from the coalescer filter to prolong element life.

B. AIR DRYER - (Refrigerated or Desiccant). An air dryer is generally

preferred for optimal results, but is optional.

C. COALESCER FILTER - Do not touch the filter element once it has

been put into service; the slightest pressure on the outer foam cover
can easily damage it once it has been used.

D. OIL VAPOR FILTER - The Type D element is an adsorption type for

removing oil vapors, oil-associated odors, whether petroleum base or
synthetic base and nearly 100% of any remaining solid contaminants.

E. DIFFEREnTIAL PRESSuRE InDICATOR - Maximum recommended

pressure drop across coalescer filters is 7 psi (0,5 bar). This can be
monitored by installing a differential pressure indicator.

F. VALVE - Do not use a valve or shut-off device in conjunction with a

coalescer filter that will allow a momentary or surge pressure drop
greater than 50 psi (3,4 bar). To avoid high surges which can either
ruin the element or momentarily allow downstream contamination,
use a slow-opening type valve.

!

CAUTION

Polycarbonate bowls, being transparent and tough, are ideal for use with
Filters and Lubricators. They are suitable for use in normal industrial
environments, but should not be located in areas where they could be
subjected to direct sunlight, an impact blow, nor temperatures outside
of the rated range. As with most plastics, some chemicals can cause
damage. Polycarbonate bowls should not be exposed to chlorinated
hydrocarbons, ketones, esters and certain alcohols. They should not be
used in air systems where compressors are lubricated with fire-resistant
fluids such as phosphate ester and diester types.
Metal bowls are recommended where ambient and/or media conditions
are not compatible with polycarbonate bowls. Metal bowls resist the
action of most such solvents, but should not be used where strong acids
or bases are present or in salt laden atmospheres. Consult the factory
for specific recommendations where these conditions exist.
TO CLEAN POLYCARBONATE BOWLS USE MILD SOAP AND
WATER ONLY! DO NOT
use cleansing agents such as acetone,
benzene, carbon tetrachloride, gasoline, toluene, etc., which are
damaging to this plastic.

Advertising