Service kits available, Operation, Service procedure – Wilkerson SM2 User Manual

Page 2

Advertising
background image

SM1 & SM2 Coalescing Filter

83-947-000

Service Kits Available

Description

SM1

SM2

Auto Drain

SRP-96-027

Auto Pulse Drain

RK504SY-SS

Element (.3 Micron)

SRP-96-005

SRP-96-006

Manual Drain

SAP05481

SAP05481

Sight Glass

SRP-96-026

SM1 Coalescing Filter

with Auto Pulse Drain

SM2 Coalescing Filter

with Sight Gauge

Operation

1. Both free moisture and solids are removed automatically by the

filter.

2. Manual drain filters must be drained regularly before the

separated moisture and oil reaches the bottom of the baffle or

end cap.

3. The filter element should be removed and replaced when

pressure differential across the filter is 69 kPa (10 psig).

Service Procedure

Caution: Shut off air supply and exhaust the pressure
trapped within the filter bowl before servicing unit.
Caution: Touching or handling the new element section
may cause contamination, spotting, or migration of oil.

1. Unscrew and remove bowl.
2. Unscrew the filter holder from body and then remove element.
3. Clean all internal parts and bowl before reassembling.
4. The coalescing filter element should be removed and

replaced when pressure differential across the filter is 10

PSID. Differential gauges should be used to determine when

the maximum recommended pressure differential has been

reached.

5. Attach filter holder and finger tighten firmly.
6. Replace bowl seal. Lightly lubricate new seal to assist with

retaining it in position.

7. Install bowl into body and tighten; hand tight, plus 1/4 turn.
8. After servicing, apply system pressure and check for air leaks.

If leakage occurs, DO Not Operate — conduct servicing

again.

!

!

SM2 Metal Bowl

with Auto Drain

Lightly grease with provided lubricant.
Inspect for nicks, scratches, and surface imperfections.
If present, reduced service life is probable and future replacement
should be planned.
Clean with lint-free cloth.

O-Ring

Bowl

(Hand Tighten)

Auto Pulse Drain

(Finger Tight)

Element

Bowl Seal

Element

O-Ring

Bowl Seal

Manual Drain

Bowl

(Hand Tighten)

Filter Body

Filter Body

O-Ring

Auto Drain

(SM2 Only)

(Finger Tight)

O-Rings

Bowl

Hand Tight

O-Rings
Seal Cap

Finger Tight
Cap Seal

Screw

Torque .56 to 1.13 Nm

(5 to 10 in. lb.)

Screw

Torque .56 to 1.13 Nm

(5 to 10 in. lb.)

Sight Glass

Bowl

Hand Tight

Advertising
This manual is related to the following products:

SM1