Wilkerson R26 User Manual

Warning

Advertising
background image

Installation & Service Instructions
83-181-000

Regulator Model R26
With Variations and Accessories

ISSUED: April, 2006
Supersedes: August, 1995

Doc.# 83181000, ECN# 060135, Rev. 1

Richland, MI 49083

Tel: (269) 629-5000

WARNING

To avoid unpredictable system behavior that can cause personal injury
and property damage:

Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.

Disconnect air supply and depressurize all air lines connected to
this product before installation, servicing, or conversion.

Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.

Medium must be moisture-free if ambient temperature is below
freezing.

Service according to procedures listed in these instructions.

Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

After installation, servicing, or conversion, air and electrical supplies
(when necessary) should be connected and the product tested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.

Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.

!

!

WARNING

Product rupture can cause serious injury.

Do not connect regulator to bottled gas.

Do not exceed maximum primary pressure rating.

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

This document and other information from The Company, its subsidiaries
and authorized distributors provide product and/or system options for further
investigation by users having technical expertise. It is important that you
analyze all aspects of your application, including consequences of any
failure and review the information concerning the product or systems in the
current product catalog. Due to the variety of operating conditions and
applications for these products or systems, the user, through its own
analysis and testing, is solely responsible for making the final selection of
the products and systems and assuring that all performance, safety and
warning requirements of the application are met.

The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by
The Company and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

!

INSTALLATION

1. Install as close as possible to where regulated air is needed.

2. Install the unit with the air flowing through the body in the direction

indicated by the arrow.

3. Install the same pipe size unit as the pipe line in use. Avoid using fittings,

couplings etc. that restrict the airflow, unless maximum flow is not
needed.

4. Regulator may be installed with the adjusting knob in any position. Attach

gauge to one 1/4" female gauge port and plug the other 1/4" female
port, or use it as a regulated outlet port.

5. Turning the adjusting screw clockwise increases the regulated pressure

and turning it counterclockwise decreases the regulated pressure.

6. Panel mount regulators require a 17/8" diameter hole and are mountable

on panels from 1/8" to 1/2" thick.

MAINTENANCE

1. The regulator can be disassembled for servicing without removal from

line.

2. Occasionally remove bottom plug and clean plug, body and valve seat

(vent air line on both sides of regulator).

3. TO DISASSEMBLE-shut off air to regulator and vent air line on both

sides of regulator. Turn adjusting screw counterclockwise to relieve
adjusting knob (panel mount nut, if used), tamper-resistant kit (on
tamper-resistant models) and cover cap. Remove the six screws, cover
and regulating spring. Diaphragm assembly can now be removed. By
removing bottom plug and spring the valve stem can be removed from
the bottom of the regulator

4. IF UNIT WILL NOT REGULATE TO DESIRED PRESSURE OR IF

PRESSURE BECOMES EXCESSIVE remove bottom plug, spring, and
valve assembly. Clean and check o-ring, valve stem and valve seat for
water damage. Replace worn or damaged parts. Install Repair Kit No.
RRP-95-951 for self-relieving models and Repair Kit No. RRP-95-950
for nonrelieving models for complete overhaul.

5. IF UNIT LEAKS AT RELIEF PORT, install proper repair kit as listed

under Repair Kits and Replacement Parts.

6. TO REPLACE BODY O-RING-This o-ring is located above a metal

washer through which the valve stem passes and which cannot be
removed. Using a pointed probe of some kind, pull o-ring out. Force
new o-ring through washer hole into o-ring cavity.

REPAIR KITS AND REPLACEMENT PARTS

SELF-RELIEVING REPAIR KIT

(includes self-relieving diaphragm assembly,
valve assembly and o-rings) ............................................ RRP-95-951

NONRELIEVING REPAIR KIT

(includes nonrelieving diaphragm assembly,
valve assembly and o-rings) ............................................ RRP-95-950

Self-Relieving Diaphragm Kit ............................................. RRP-96-238

Nonrelieving Diaphragm Kit ............................................... RRP-96-332

Valve Assembly (valve stem, valve spring) ........................ RRP-96-294

Regulating Springs:

0-60 psi ............................................................................ RRP-95-962

0-125 psi .......................................................................... GRP-95-225

0-250 psi .......................................................................... RRP-95-219

Adjusting Knob Assembly .................................................. RRP-95-023

ACCESSORIES
Panel Mount Nut ................................................................ RRP-95-954

Wall Mounting Bracket ........................................................ RPA-95-947

Wall Mounting Bracket (for 26 Series Combo’s) ................ GRA-95-956

Tamper Resistant Kit ........................................................... RPA-95-006

Gauges:

0-60 psig ....................................................................... K4520N14060
0-160 psig ..................................................................... K4520N14160
0-300 psig ..................................................................... K4520N14300