Installation & Service Instructions:
2L300C
1" Lubricator Series
ISSUED: August, 2006
Supersedes: November, 2003
Doc.# 2L300, ECN# 060900, Rev. 7

Pneumatic Division
Richland, Michigan 49083
269-629-5000

Application Limits

These products are intended for use in general purpose
compressed air systems only.

kPa

PSIG

bar

Operating Pressure Maximum

1700

250

17.0

Operation and Service

(Refer to Pictorial on Following Page)
1. Filling — The Mist lubricator can be filled without turning off

the upstream pressure. Slowly remove the fill plug by turning

counterclockwise. This allows the bowl pressure to vent.

Suggested lubricant: F442
Petroleum based oil of 100 to 200 SUS viscosity at 100°F and

an aniline point greater than 200°F. (Mobil DTE24 and Sun

Company Sunvis 932 are good examples). Do not use oils

with adhesives, compound oils containing solvents, graphite,

detergents or synthetic oils.

2. Replace the fill plug (by turning clockwise) and seat firmly.

Excessive torque is not required. If leakage occurs,

DO NOT

OPERATE — conduct repairs again.The lubricator is now

ready for setting.

3. Oil delivery adjustment — To adjust oil delivery, turn adjustment

knob on top of the lubricator.

Lubricator

w/ Manual Drain

Lubricator

Less Drain

CAUTION

Polycarbonate bowls, being transparent and tough, are ideal for use with
Filters and Lubricators. They are suitable for use in normal industrial
environments, but should not be located in areas where they could be
subjected to an impact blow, nor temperatures outside of the rated range.
As with most plastics, some chemicals can cause damage. Polycarbonate
bowls should not be exposed to chlorinated hydro-carbons, ketones,
esters, and certain alcohols. They should not be used in air systems where
compressors are lubricated with fire resistant fluids such as phosphate
esters and di-esters types. In areas where polycarbonate bowls are
exposed to high temperatures or atmospheres containing vapors or fluids,
which are damaging to plastic, use metal bowls.
Metal bowls resist the action of most such solvents but should not be used
where strong acids or bases are present or in salt laden atmospheres.
Consult the factory for specific recommendations where these conditions
exist.
TO CLEAN POLYCARBONATE BOWLS USE MILD SOAP AND WATER
ONLY! DO NOT
use cleaning agents such as acetone, benzene, carbon
tetrachloride, gasoline, toluene, etc., which are damaging to this plastic.

Introduction

Follow these instructions when installing, operating, or servicing
the product.

Operating Temperature Maximum

80°C (175°F)

Operating Temperature Minimum

0°C (32°F)

ANSI Symbol

Installation

1. The lubricator should be installed with reasonable accessibility

for service whenever possible. Keep pipe or tubing lengths to a

minimum with inside clean and free of dirt and chips. Pipe joint

compound should be used sparingly and applied only to the

male pipe – never into the female port. Do not use PTFE tape

to seal pipe joints – pieces have a tendency to break off and

lodge inside the unit, possibly causing malfunction.

2. Install lubricator so air flows in the direction of arrow on body.
3. Installation should be upstream of the device it is to lubricate

(valve, cylinders, tool, etc.).

WARNING

To avoid unpredictable system behavior that can cause personal injury

and property damage:
• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to this

product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how

pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical supplies

(when necessary) should be connected and the product tested for

proper function and leakage. If audible leakage is present, or the

product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered by

paint, etc. If masking is not possible, contact your local representative

for replacement labels.

!

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE

PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS

CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its

subsidiaries and authorized distributors provide product and/or system options

for further investigation by users having technical expertise. It is important

that you analyze all aspects of your application, including consequences of

any failure and review the information concerning the product or systems

in the current product catalog. Due to the variety of operating conditions

and applications for these products or systems, the user, through its own

analysis and testing, is solely responsible for making the final selection of the

products and systems and assuring that all performance, safety and warning

requirements of the application are met.
The products described herein, including without limitation, product features,

specifications, designs, availability and pricing, are subject to change by Parker

Hannifin Corporation and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION

IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.

CONTACT YOUR LOCAL REPRESENTATIVE.

!

Safety Guide

For more complete information on recommended application
guidelines, see the Safety Guide section of Pneumatic Division
catalogs or you can download the

Pneumatic Division Safety

Guide at: www.parker.com/safety

Bowl guards are recommended for added protection of
polycarbonate bowls where chemical attack may occasionally
occur.

!

Advertising