Wilkerson XB3 User Manual

Warning, Caution, Safety guide

Advertising
background image

Richland, MI 49083

Tel: (269) 629-5000

Installation & Service Instructions
84-006-000
Drain Model XB3
with Variations and Accessories
ISSUED: February, 2007
Supersedes: October, 1997

Doc. #84006000, EN# 061219, Rev. 2

Bowl guards are recommended for added protection of polycarbonate bowls
where chemical attack may occasionally occur.

!

WARNING

To avoid polycarbonate bowl rupture that can cause personal injury or
property damage, do not exceed bowl pressure or temperature ratings.
Polycarbonate bowls have a 150 PSIG pressure rating and a maximum
temperature rating of 125°F.

WARNING

To avoid unpredictable system behavior that can cause personal injury
and property damage:

• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to this

product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical supplies

(when necessary) should be connected and the product tested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered by

paint, etc. If masking is not possible, contact your local representative
for replacement labels.

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE

PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED

ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY

DAMAGE.

This document and other information from The Company, its subsidiaries

and authorized distributors provide product and/or system options for further

investigation by users having technical expertise. It is important that you

analyze all aspects of your application, including consequences of any failure

and review the information concerning the product or systems in the current

product catalog. Due to the variety of operating conditions and applications for

these products or systems, the user, through its own analysis and testing, is

solely responsible for making the final selection of the products and systems

and assuring that all performance, safety and warning requirements of the

application are met.
The products described herein, including without limitation, product features,

specifications, designs, availability and pricing, are subject to change by The

Company and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR

INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE

THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

!

!

!

CAUTION

Polycarbonate bowls, being transparent and tough, are ideal for use with
Filters and Lubricators. They are suitable for use in normal industrial
environments, but should not be located in areas where they could be
subjected to direct sunlight, an impact blow, nor temperatures outside of
the rated range. As with most plastics, some chemicals can cause damage.
Polycarbonate bowls should not be exposed to chlorinated hydrocarbons,
ketones, esters and certain alcohols. They should not be used in air systems
where compressors are lubricated with fire-resistant fluids such as phosphate
ester and diester types.
Metal bowls are recommended where ambient and/or media conditions are
not compatible with polycarbonate bowls. Metal bowls resist the action of
most such solvents, but should not be used where strong acids or bases
are present or in salt laden atmospheres. Consult the factory for specific
recommendations where these conditions exist.
TO CLEAN POLYCARBONATE BOWLS USE MILD SOAP AND WATER
ONLY! DO NOT
use cleansing agents such as acetone, benzene, carbon
tetrachloride, gasoline, toluene, etc., which are damaging to this plastic.

Safety Guide

For more complete information on recommended application guidelines, see
the Safety Guide section of Pneumatic Division catalogs or you can download
the

Pneumatic Division Safety Guide at: www.wilkersoncorp.com

MANUAL OVERRIDE ASSEMBLY
1. Screw female end with actuator rod onto threaded end of automatic drain.
2. Tighten in place using a 7/16" (12mm) wrench on drain thread flats.
3. Secure manual override finger tight plus 1/2 turn.
4. WARNING: Do not over tighten. Use pipe sealant sparingly.
INSTALLATION
1. Refer to the above warning.
2. Install unit in a vertical position.
3. Piping to this unit should be taken from the bottom of air line, sump, reservoir

or pneumatic device to be drained.

4. A drain line of 3/8" or 10mm flex tubing may be attached to drain port, if

desired. Too much restriction can hinder draining action.

5. Do not use rigid plumbing for discharge port at bottom of drain; use flexible

hose connections to dampen plant vibrations from traveling into the drain.

6. The maximum pressure and temperature ratings for transparent plastic bowls

are 150 psig (10,3 bar) and 125°F (51,7°C); and for metal bowls, 200 psig
(13,8 bar) and 150°F (65.5°C).

MAINTENANCE
1. Under normal operating conditions, this product should be trouble-free.
2. Before removing bowl shut off air supply and reduce pressure in unit to

zero.

3. Occasionally clean the screen of the automatic drain.
4. DO NOT PRESSURIZE UNIT unless bowl and bowl guard are reinstalled and

the clamp ring is securely locked in place.

REPAIR KITS AND REPLACEMENT PARTS
Plastic Bowl (5-oz. size)

with Automatic Mechanical Drain and Bowl Guard ................... GRP-95-845

Bowl Guard (5-oz. size) ................................................................. GRP-95-846
Metal Bowl with Automatic Mechanical Drain

and Fluorocarbon Seals ......................................................... GRP-96-007

Automatic Mechanical Drain ......................................................... GRP-95-973
Automatic Mechanical Drain (BSP Model)..................................... GRP-96-200
Automatic Mechanical Drain with

Flourocarbon Seals ................................................................ GRP-95-981

Manual Override ............................................................................ GRP-96-001
Manual Override (BSP Model) ....................................................... GRP-96-101