INSTALLATION

1. Refer to WARNING prior to installation.

2. Install as close to the point of use as possible.

3. Unit must be installed with the flow in the direction of the flow arrow on

face of shut off blade.

4. Avoid using reducing bushings, couplings, etc., whenever possible to

install this product. These devices restrict air flow and can affect
performance.

5. Maximum pressure rating is 150 psig (10.3 bar). Temperature range is

32°F to 150°F (0°C to 65.5°C).

6. Unit can be locked in the closed position using a standard padlock.

MAINTENANCE

THE UNIT MUST BE REMOVED FROM THE COMPRESSED AIR LINE.

1. Remove retaining screws, and separate body halves.

2. Remove shut off blade.

3. Remove O-rings from body halves.

4. Lightly lubricate O-rings and place in grooves on body halves.

5. Align shut off blade on pivot pin located on outlet body half as shown.

6. Place body halves together and tighten screws to approximately 20 in/lbs.

Installation & Service Instructions
84-021-000

Safety Lockout Valve Model V08

ISSUED: March, 2005
Supersedes: April, 2002

Doc. #84-021-000, Rev. 2

Richland, MI 49083

Tel: (269) 629-5000

WARNING

To avoid unpredictable system behavior that can cause personal injury
and property damage:

Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.

Disconnect air supply and depressurize all air lines connected to
this product before installation, servicing, or conversion.

Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.

Medium must be moisture-free if ambient temperature is below
freezing.

Service according to procedures listed in these instructions.

Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

After installation, servicing, or conversion, air and electrical supplies
(when necessary) should be connected and the product tested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.

Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.

!

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY
DAMAGE.

This document and other information from The Company, its subsidiaries
and authorized distributors provide product and/or system options for further
investigation by users having technical expertise. It is important that you
analyze all aspects of your application, including consequences of any
failure and review the information concerning the product or systems in the
current product catalog. Due to the variety of operating conditions and
applications for these products or systems, the user, through its own
analysis and testing, is solely responsible for making the final selection of
the products and systems and assuring that all performance, safety and
warning requirements of the application are met.

The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by
The Company and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

!

Advertising