INSTALLATION

1. Refer to Warnings prior to installation.

2. Install as close to the point of use as possible.

3. Unit must be installed with the flow in the direction of the flow arrow

on top of the body.

4. Avoid using reducing bushings, couplings, etc., whenever possible

to install this product. These devices restrict air flow and can affect
performance.

5. Maximum pressure rating is 150 psig (10.3 bar). Temperature

range is 32°F to 150°F (0°C to 65.5°C)

6. Unit can be locked in the closed position using a standard padlock.

MAINTENANCE

THE UNIT MUST BE REMOVED FROM THE COMPRESSED AIR LINE.

1. Remove retaining screws, and separate body halves.

2. Remove shut off blade.

3. Remove o-rings from body halves.

4. Lightly lubricate o-rings with Magnalube-G or equivalent and place

in grooves on body halves.

5. Align shut off blade on pivot pin located on outlet body half as shown.

6. Place body halves together and tighten screws to approximately

20 in/lbs.

Richland, MI 49083

Tel: (269) 629-5000

Installation & Service Instructions
83-543-000

Safety Lockout Valve
Models V19 and V29

ISSUED: February, 2005
Supersedes: August, 2002

Doc. #83-543-000, Rev. 2

WARNING

To avoid unpredictable system behavior that can cause personal injury
and property damage:

Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.

Disconnect air supply and depressurize all air lines connected to
this product before installation, servicing, or conversion.

Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.

Medium must be moisture-free if ambient temperature is below
freezing.

Service according to procedures listed in these instructions.

Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

After installation, servicing, or conversion, air and electrical supplies
(when necessary) should be connected and the product tested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.

Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.

!