Instruction Manual / DE0, DE1 and DE2

83-918-000 6/98

Wilkerson Compact Heatless Air Dryers

MODELS DE0, DE1 AND DE2 TROUBLESHOOTING GUIDE

B

PROBLEM: RESTRICTED FLOW THROUGH UNIT

POSSIBLE CAUSE

CHECK

CORRECTIVE ACTION

B1 Incoming power interrupted.

Check the power supply. Measure

If voltage is present, replace

for voltage at the cycle timer.

timer.

B2 Improper operating conditions.

See A1, A2, A3 above.

B3 Dirty or obstructed inlet air

See A4 above.

filter.

B4 Improper plumbing.

Make sure inlet and outlet

Correct plumbing.

connections are not reversed.

B5 Plugged air passage.

Check inlet and outlet air

Clear restrictions.

passages and piping for
blockages.

B6 Solenoid coil burned out.

See A6 above.

B7 Timer not operating properly.

See A8 above.

B8 Solenoid core spring broken.

See A11 above.