Power endplate controls, 12v hookup – Zapco C2K User Manual

Page 33

Advertising
background image

33

Power Endplate Controls


1. Power On / Protect indicator: Glows green when amplifier is on. Turns

red when amp is in protection.

2. Turn On Delay: Since some decks take longer than others to turn on,

we have included an adjustment on the

C2K amps to lengthen their

turn-on delay. This will eliminate any dangerous turn-on pops.

3. RSD Port: All

C2K amps will support a remote mount status display to

provide a visual check on amp functions.

4. Power connectors: See chart below for appropriate wire size. Use of

small gauge wire will greatly restrict amplifier performance. Always use
the same size wire for both Power (+12V) and Ground (-12V).

5.

Main Power Fuses: Fuse sizes are listed on the I.D. plate above the
fuses. If the fuses should blow, always, replace with the fuse rating
on the I.D. plate.

2.5X: 15 amp fuses

4.0X: 25 amp fuses



12V Hookup

The use of small gauge wire will greatly reduce the power potential of

your

C2K Amplifier. Please observe the following minimum wire gauges.

Since electricity works only when it travels in a full circle, please

remember that the ground connection must use the same size wire as the
power connection.


Amplifier Run less than 10 ft Run over 10 ft

2.5x 10 Gauge 8 Gauge

4.0X 8 Gauge 4 Gauge

When using multiple amps, use a 4 gauge Minimum to run to a

junction block, close to the amps. If possible, run 2 or 0 gauge to the
junction block, as any current loss will result in a loss of power.

Advertising