~ Appendix E: Serial Commands

47

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

AD

This command changes the state of the auto disconnect function.

[DEVICE] AD <X>

Explanation

<X>

X=0

Parameter to set Auto Disconnect to OFF

X=1

Parameter to set Auto Disconnect to LOOP

X=2

Parameter to set Auto Disconnect to Call

Progress (CP)

X=3

Parameter to set Auto Disconnect to LOOP+CP

X=Null

Parameter to report back the current state

Return Values

The command will return the updated connection state of the unit

in the same format as the command. If the sent command changes

the state of the unit, the updated state is returned.

If:

Command returns:

current disconnect state is OFF

[DEVICE] AD 0

current disconnect state is LOOP

[DEVICE] AD 1

current disconnect state is CP

[DEVICE] AD 2

current discon. state is LOOP+CP

[DEVICE] AD 3

AGC

This command changes or reports back the state of the AGC

for a microphone or line input.

[DEVICE] AGC <CH> <X>

Explanation

<CH>

CH= 1-4

Parameter to apply to the

specified microphone channel

CH= A-D

Parameter to apply to the

specified line input

CH= *

Parameter to apply command

to all microphone channels

<X>

X=0

Parameter to set the state to OFF

X=1

Parameter to set the state to ON

X=2

Parameter to toggle the state from one

state to the other (regardless of current

state)

X=Null

Parameter to return the current state

Return Values

The command will return the updated condition (On=1,

Off=0) of the AGC in the same format as the command.