Assembly, Operation – Chicago Electric 38347 User Manual

Page 5

Advertising
background image

#38347 Page 5

Assembly

1. The Handle for the Lid (#4) needs to be assembled. Remove nuts and washers from Handle. Place Handle
in place on front portion of Lid and tighten screws with washers and nuts.

2. Attach the black plastic Filter to the Pump (#28). It fits over the wide opening on the side of the Pump.

3. Attach the Flexible Pipe (#27) to the Pump. It screws on the small open fitting on the top of the Pump.

4. Set the Work Shelf (#42) on the Body (#1).

Operation

1. Parts can soak in the Body, but should not be left overnight. Use the Work Shelf when using
the Flexible Pipe and while cleaning small parts.

Filter

Work Shelf

Flexible Pipe

KNOW YOUR SOLVENTS. Do not use any highly volatile, flammable or combustible solvents.
Caution: Parts being cleaned may leave flammable or combustible residue, or may contain
flammable or combustible fluids that remain in the parts washer. Check for solvent fumes to
verify non-flammability and non-toxicity. Use in a well ventilated area. NO SMOKING!

Only use non-corrosive water based solvents. Never use highly volatile flammable solvents
such as gasoline, toluene, or diesel fuel. Non water based solvents may also contain fumes
that are hazardous to your health, and must not be used at any time. Keep away from any
ignition sources. Immerse the pump in liquid while operating. Fluid should be replaced and
parts washer cleaned on a regular basis to avoid hazardous conditions. Avoid solvent contact
with skin and eyes. Chlorinated solvents, such as 1-1-1 Trichloroethane and Methylene Chlo-
ride (also known as Methyl Chloride) can chemically react with aluminum and may explode.
Many tools and equipment contain aluminum. If you are in any doubt whatsoever, contact the
solvent manufacturer.

Note: The fusible link must be intact at all times.

Rev 06/01

Advertising