Combination Heating/Cooling Units

INTRODUCTION

The 48DH, DL and DM combination heating/

cooling units are complete systems designed for
outdoor installation on slab or rooftop.

Installation consists of: rigging and mounting

the unit; attaching ductwork; making single gas,
electrical and condensate connections; and attach­
ing thermostat leads. A field-furnished filter rack is
required in the return air stream.

RECEIVING THE UNIT

Examine the unit carefully for any damage

incurred in shipment. If found, file claim with
transportation company immediately.

Check unit nameplate to ensure that unit

electrical requirements match available power
supply, and that unit is designed for use with the
proper gas type (natural or liquefied petroleum).

Leave unit on shipping skids until ready for

mounting.

INSTALLATION

Check national and local gas and electrical

codes and local building codes for any special
installation requirements.

Unit Location

— Install unit outdoors and as close

to building duct openings as possible. Unit may
face in any direction since neither the condenser
air inlet nor the flue outlet (Fig. 1) are affected by
wind. Do not locate unit near sources of con­
taminated air.

Although the unit is weatherproof, position

unit so that water and ice from roofs or eaves
cannot fall directly on the unit.

SPACE LIMITATIONS - Provide sufficient space
for unimpeded air flow and for wiring and servicing
unit (Fig. 1).

,

CONO UNIT

2-0 OVERHEAD SPACE SECTION

REQ FOR SERVICE AND ACCESS PANEL

AIR FLOW

;

002

'

o n l y

.

.JSSiiSOc

045 8005

HEATING
SECTION

i ACCESS PANEL

SERVICE ^

OPENINGS

^0'

BOTH

s i d e

:

ACCESS SIDE

FLUE OUTLET

—,

—X::...

n DIAM HOLE

® FOR LINE

POWER WIRING

____WIND CAP ASSEMBLY (CONDENSER AIR OUTLET

îLÎÎÎ

002 UNIT ONLY)

COMBUSTION AIR

• DIAM*

(S

m

TG HOLES)

*This dimension is not applicable to 002 units because there are no

mounting rails

Space required for service Design certified by A G.A. for in-

stallation on combustible type floor with a minimum ciear-

ta-'iiEiEJ ance space of 1 in. on duct connection side, and 12 in on

remaining sides

O'

Indoor (Evaporator) Air

Fig. 1 — Physical Data

Table 1 — Base Unit Dimensions (ft-in.)

) Condenser Air

UNIT

48DL

48 DH

48DL

48DL

48 DM

48 DH

48DL

48DL

48DH

002*

003

004

Q45

005

A

3-10

3-10

4- 7

4- 7

3_2

5- 2

5- 2

5- 2

5- 7

\

В

4- 7

%

4- 7

%

5-2У

5- 2

%

5- 2

%

5- 2У

5- 8У

C

0

-

1 0

V

3

0 - 1

оу

0

-юу

0 - 1

оу

1-ЗУ

1- 5У

1- ЗУ

1- ЗУ

1 9

D

0-11 Уз

0 - 1 1

у

1- 2

1- 8

1-8

1- 8

1-11

1-11

1-11

E

1- 0

1- 0

1- 0

1- 0

1-0

1- 0

1- 0

1- 0

1

- оу

F

2- 2У

2- 2

%

2- 2У

2- 2У

2-2У

2- 2У

2- 2

%

2- 2

%

2- 2У

G

2- 2У

2- 2У

2-4У

2- 2Ув

2- 4У

2- 4У

2- 4У

H

0-11У

0-11У

0-11У

0-11У

1-4У

1- 4У

1- 4У

1- 4У

1- 4У

J

0- 4

0- 4

0- 4

0- 4

0-7У

0-11

0- 7У

0- 7У

1- 2У

*Refer to Table 2 for differences of these series