For opposite airflow, A caution, Fig. 10—wire routing – Carrier 31KAX User Manual

Page 5

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Fig. 7—Installing Baffles if Needed

for Opposite Airflow

from cleaner casing by pulling it towards you. This motion
disengages power supply connector.

3. Slide out prefilters and air cleaner cells.

4. For Model 016 electronic air cleaner furnace side applica­

tion, cut open return knockout at the side of the furnace
cabinet. For Models 012 and 020, cut opening as shown in
Fig. 5 opening detail.

5. In order to prevent air leakage, use foam tape provided to

attach air cleaner to side of furnace or system blower.

NOTE:

The unit is shipped for furnace right side application.

For left side application, rotate rear mounting flange 180 ° by re­
moving (4) screws in the back of the air cleaner. Be sure all four

screws are in place after the rotation. Relocate the junction box
on the furnace to the right side, if required.

6. Hook back flange into the opening. Use air cleaner cabinet

front support flange adjacent to the unit as template and

drill two holes on furnace casing. See Fig. 6.

7. Secure the unit with (2) screws using screws provided into

drilled holes. See Fig. 6.

8. Prepare return-air duct for installation to unit. Return air

must use full cabinet opening. Duct should run straight
into unit.

A CAUTION

If flanged sheet metal ducts are metal-screwed to the unit
casing, do not use screws longer than 1/2-in.

Fig. 9—Line-to-Line Wiring Diagram

A CAUTION

Airflow across air cleaner must be uniform for best results.
Install turning vanes if air cleaner is installed close to an
elbow. Depending on size of furnace, it may or may not be
necessary to reduce ductwork on leaving-air side of air
cleaner. For any application, maintain a 3-to-l duct reduc­

tion ratio (3-ins. of duct length for every 1-in. of reduction

in size).

BLK

WIRE CONN.

-Hg-------

WHITE <

ON 208/240 UNITS ONLY

I FIELD WIRING

------------ FIELD WIRED GROUND

WHITE

TRANSFORMER ASSY.
FOR FIELD CONN. WHT

BLK

INTERLOCK

(DO NOT BYPASS)

3

POWER

SWITCH

UNIT

OPERATION LIGHT

A89116

Fig. 10—Wire Routing