TECHNICAL INFORMATION FOR THE
INSTALLER

Before installing the cooktop, remove the protective film.

These cooking hobs are designed to be embedded into kitchen
fixtures measuring 600 mm in depth and from 20 to 40 mm
thick, for 2 electrical plates hob, and from 30 to 40 mm thick for
vitroceramic hob.

In order to install the cooker top into the kitchen fixture, a hole
with the dimensions shown in figs. 6.8a and 6.8b has to be
made, keeping in consideration the following:

– within the fixture, between the bottom side of the cooker top

and the upper surface of any other appliance or internal shelf
there must be a clearance of at least 30 mm;

– the cooker top must be kept no less than 50 mm away from

any side wall;

– the cooker top must be kept at a distance of no less than 50

mm from the rear wall.

– there must be a distance of at least 650 mm between the hob

and any wall cupboard or extractor hood positioned immedi-
ately above (see figs. 6.9a and 6.9b).

– the coatings of the walls of the unit or appliances near the

cooktop must be heat resistant ("Y" protection against heat-
ing in compliance with standards EN 60335-2-6).

Do not instal the appliance near inflammable materials (eg.
curtains).

ELECTRICAL PLATES AND VITROCERAMIC COOKING HOBS

490

510

270

288

30

+ 0

– 2

+ 0

– 2

50

Fig. 6.8a

490

510

270

288

+ 0

– 2

+ 0

– 2

50

650 mm

50 mm

450 mm

Fig. 6.9b

Fig. 6.9a

650 mm

50 mm

450 mm

Fig. 6.8b