Gas-Fired Forced-Air Furnace

with Electronic Ignition

INSTALLATION

Before installing the furnace, refer to “Pro­

cedures for Gas-Fired Furnaces” (packaged with the
equipment) for information concerning com­

bustion, venting, piping, and other standard instal­
lation practices. Further reference is made to the

current edition of the American National Standard
Z223.1 National Fuel Gas Code.

Each furnace is shipped from the factory com­

pletely assembled with multispeed direct-drive
blower and wired ready for indoor heating installa­
tion. All sizes feature a printed-circuit board control

center with easy-to-read low-voltage terminal strip
to ensure proper connections. The control center

also provides easy connections for line-voltage
air cleaners.

CAUTK)?i : Do not iosiaB famace in a corrosive
or contasninated atmospheres Miakesnre that ail
local ordinances for combnstion and oircalating
air supply axe observed.

Table 1 — Clearances (in inches)

SIZES

050 & 075

100 thru 175

Sides

Single Wall Vent

f

. .

Type B — Double Wall Vent

0

1

Back

0

0

Top of Plenum

1

1

Vent Connector

Single Wall

6

6

Type B — Double Wall

_____

______ 1 _

Front____ ________ ____________

Combustion Air

........

“e

6

Service

30

30

Installation comprises the following:

Inspection .................................................................... *
Location, Ventilation and Air

for Combustion........................................................*

Gas Piping.................................................................... *
Venting......................................................................... *
Electrical ................................................................... 1
Filter............................................................................. 7
Start-Up, Adjustment, and Safety Check............... 8

Service....................................................................... 11

*To perform these installation steps, refer to the appropriate

sections of “Procedures

for Gas-Fired Furnaces” booklet

packaged with this unit.

The design of the upflow gas-fired furnaces is

A.G.A. certified for installation on combustible

flooring in alcoves, basements, closets, or utility
rooms.

For accessory installation details, i.e., automatic

vent damper, humidifier, electronic air cleaner, etc.,

refer to applicable installation literature.

Electrical Connections

LINE VOLTAGE WIRING
IMPORTANT: Before proceeding with the elec­

trical connections, make certain that voltage,
frequency, and phase correspond to that specified
on the unit rating plate. Also, check to be sure that
the service provided by the utility is sufficient to

handle the additional load imposed by this equip­
ment. Refer to the unit rating plate for equipment

electrical requirements.

K0'S(4)

RETURN AIR OPENING

(SIDE) (FIELD CUT EITHER

SIDE) BEND FLANGES UP 90'
*B0TT0M OPENING

ISsjlj SERVICE CLEARANCE C> AIRFLOW

Certified dimension drawings available on request

Fig. 1 — Dimensions