LEGEND

GROUND SCREW

(NOTE #1)

ALS 1# AUXILIARY LIMIT SWITCH-MANUAL RESET
ALS 2# AUXILIARY LIMIT SWITCH-AUTOMATIC RESET

BLWR BLOWER MOTOR RELAY
BLWM BLOWER MOTOR
CPU MICROPROCESSOR AND CIRCUITRY
DSS DRAFT SAFEGUARD SWITCH
EAC-1 ELECTRONIC AIR CLEANER CONNECT I ON(115V AC)(1 AMP MAX.)

EAC-2 ELECTRONIC AIR CLEANER CONNECT I ON(COMMON)
FSE FLAME SENSING ELECTRODE

HSI

HOT SURFACE IGNITOR

(115V AC)

HSIR

HOT SURFACE IGNITOR

RELAY

HUM-1 24VAC HUMIDIFIER CONNECTION (.5 AMP. MAX.)
HUMR HUMIDIFIER RELAY

ILK BLOWER DOOR INTERLOCK SWITCH
I DM

INDUCED DRAFT MOTOR

I DR

INDUCED DRAFT RELAY

LO/HI BLOWER MOTOR SPEED CHANGE RELAY
L0T#1 LIMIT OVERTEMPERATURE-MANUAL RESET

L0T#2 LIMIT OVERTEMPERATURE-MANUAL RESET

LS LIMIT SWITCH, OVERTEMPERATURE-AUTO RESET
MGV GAS VALVE-REDUNDANT OPERATORS
MGVR MAIN GAS VALVE RELAY
PL1 11-CIRCUIT EDGE CONNECTOR
PL2 2-CIRCUIT HSI CONNECTOR
PL3 2-CIRCUIT IDM CONNECTOR

PL4 1-CIRCUIT FS CONNECTOR
PL5 5-CIRCUIT BLWM CONNECTOR
PLB 2-ClRCUlT 115V AC CONNECTOR
PRS PRESSURE SWITCH
TRAN TRANSFORMER-115V AC/24V AC
TP1-TP7 TEST POINT (1) THRU (7)

—•---------JUNCTION

O

UNMARKED TERMINAL

— TERMINAL FACTORY CONNECTOR

MARKED TERMINAL

— FACTORY WIRING C120V AC)

FACTORY WIRING C24V AC)

-

— — FIELD WIRING C120V AC)

' = CONDUCTOR ON PCB1

0

FIELD WIRING SCREW TERM.

^ FIELD GROUND

EQUIP. GROUND

FIELD SPLICE

-) )— PLUG RECEPTACLE

|L1 L2

I

g

ND

NOTES;

1. COMMON SIDE CSEC-2 AND C3 OF 24V AC TRANSFORMER CONNECTED TO

GROUND THROUGH THIS MOUNTING SCREW.

2.

IF ANY OF THE ORIGINAL EQUIPMENT HIRE IS REPLACED USE WIRE

RATED FOR 105 C, OR EQUIVALENT.

3.

INDUCER AND BLOWER MOTORS CONTAIN INTERNAL AUTO-RESET THERMAL

OVERLOAD SWITCHES.

4. BLOWER MOTOR SPEED SELECTIONS ARE FOR AVERAGE CONDITIONS.

SEE INSTALLATION INSTRUCTIONS FOR DETAILS ON OPTIMUM SPEED
SELECTION.

5. USE COPPER HIRE ONLY BETWEEN THE DISCONNECT SWITCH AND THE

FURNACE JUNCTION BOX.

310278-401 REV. G