Compressor on steel base and support stand, Table 7 - concrete base dimensions (fig. 8), Fig. 10 - typical assembled condenser package 5 – Carrier 5H User Manual

Page 5

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Table 7 - Concrete Base Dimensions (Fig. 8)

DIMEN

5F

(in )

20 1 30

40

60

40

60

A

36

48

53

57

В

19

26

28

30

C

7 1 9

10

13

14

D

33-1/8

45

-

-

cr

20.2*

25.5*

30.7 *

t

19.31

26.6t

32.21

F

8

10

G

5

5-1/2

H

2-7/8

6

6-23/32 7-3/4

8-1/2

J

5-l/32|6-15/16 9-1/2 10-1/2

11-1/2

12

к

9-9/16

7-1/8

-

L

1/2

5/

м

3

4

N

1-1/2

1-3/4

P

2

2-1/4

Q

_

45

-

-

R

-

1-3/4

. . . 2

-

-

*1450 rpm.

80

60

40

15

120

71

37

16

66

38.2*
36.71

14-1/2

5-1/2

14-1/2

16-1/2 18-1/2

12

6

2

-

1/2

[

2

-

1/2

66

1-3 M

1 1750 rpm.

Table 8 - Distance Between Compressor and

Flywheel Centerlines (Fig. 8)

COMPR

SIZE

5F20

5F30

5F40

5F60

5H40

5H60

5H80

5H120

MOTOR

COMPRESSOR

BELTS

D1MEN X

HP

RPM

(No.) Size

(in.)

5,7-1/2,10

1750 & 1450

(2)

В

7-15/16

5
7-1/2

1450
1750

(2)

В

9-21/32

7-1/2

10,15

1450

1750 & 1450

(3)

В

10-31/32

7-1/2,10,15,20

1750 & 1450

(3)

В

10-3/4

10,15,20

1750 & 1450

(3)

В

11-7/16

10,15,20,25

1750 & 1450

(4)

В

11-13/16

20,25,30,40,50

1750 & 1450

(3)

С

13-3/8

30,40,50

1450

(5)

С

13-3/4

30

1750 & 1450

(3)

С

14-1/8

30

1450

(5)

С

14-1/2

40,50

1750 & 1450

(5)

С

14-1/2

60,75

1750

(5)

С

14-1/2

40,50

1750

(5)

С

20-1/2

40,50

1450

(6)

С

18-5/8

60

1750 & 1450

(6)

С

18-5/8

75

1750

(6)

С

18-5/8

60,75

1450

(9)

С

21-3/8

100

1750

(9)

с

21-3/8

60

1750

(9)

с

20-5/8

60

1450

(9)

с

21-1/2

75,100

1750 & 1450

(9)

с

21-1/2

Fig. 9 - Typicai Vibration Isolator Mounting

denser so hot gas inlet is on top and ends over­
hang stands same distance on each end.

Assemble upper straps loosely around the

condenser.

Compressor on Steel Base and Support Stand -

Place compressor unit on top of condenser stands
and bolt into place with capscrews and lock
washers provided.

HOT GAS INLET

' TAPPED MOUNTING

■.y,. HOLE

NAMEPLATE

UPPER STRAP

FABRICA STRIP

' IPS VENT PLUG

WATER CONN. INLETS FOR 4-PASS

(5F40,60); 3-PASS ON 09RH

BOTTOM FOR INLET, TOP FOR

OUTLET FOR 8-PASS (5F40,60l;

6-PASS ON 09RH

WATER CONN

OUTLET
FOR 4-PASS
(5F40,60) 3-PASS
09RH. PLUG FOR

6-PASS AND 8-PASS

*5F20 AND 30 HAVE FRANGIBLE DISC

RELIEF VALVE 385 PSIG ON
5F40.60 AND ALL 09RH *

WATER PRESSURE REGULATOR CONN

LIQUID SHUT-OFF VALVE

TAPPED MOUNTING HOLE

CONDENSER STAND

LOWER STRAP (MOUNTED TO UNDER
SIDE OF CONDENSER STAND)

Fig. 10 - Typical Assembled Condenser Package

5

Advertising