Flexlock fls roof edge dimensions, Print approval, Quantities – Flex FLS Roof Edge User Manual

Page 2: Flexlock fls roof edge, Material, Ckd by: sak, Print approval 45

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

FLEXLOCK FLS ROOF EDGE

____________________________FULLY ADHERED OR MECHANICALLY ATTACHED SINGLE-PLY VERSION

FA-50 TO FA-80 ANSI/SPRI ES-1 DESIGN PRESSURE OF 160 psf FA-95 TO FA-125 ANSI/SPRI ES-1 DESIGN PRESSURE OF 110 psf

FASCIA COVER (12'-0" [3.65 m] LENGTHS)

• 24 GA. (.65 mm) SPRING CLIP 4'-0" (1.22 m) O.C.

24 GA. (0.65 mm)
GALV. STEEL

WATERDAM

r

MEMBRANE

NOTES:

FASCIA INCLUDES 3 1/2" (89 mm)

WIDE SPLICE PLATE AT JOINTS.

FASCIA IS TO BE INSTALLED PER SPECIFICATIONS AND FLEX'S
INSTALLATION INSTRUCTIONS DWG. # 28110-11350

HOLES PRE-PUNCHED 6" (152 mm) O.C.

FASTEN PER JOB REQUIREMENTS.

1 1/4" (32 mm) GALV. RING SHANK

ROOFING NAILS PROVIDED

FASTEN PRE-PUNCHED WATERDAM 12" (305 mm)
O.C. WITH 1 1/4" (32 mm) GALV. RING SHANK

ROOFING NAILS (PROVIDED)

FLEXLOCK FLS ROOF EDGE DIMENSIONS

PRODUCT

ID. NO.

H

DIM

X

DIM

NAILER

COVERAGE

□ FA-50

5 1/4" (133 mm)

2 7/8"

(73 mm)

1 NAILER

□ FA-65

6 3/4" (171mm)

4 3/8"

(111 mm)

2 NAILERS

□ FA-80

8 1/4" (210 mm)

5 7/8"

(149 mm)

3 NAILERS

□ FA-95

9 3/4" (248 mm)

7 3/8"

(187 mm)

4 NAILERS

□ FA-110

11 1/4" (286 mm)

8 7/8"

(225 mm)

5 NAILERS

□ FA-125

12 3/4" (324 mm)

10 3/8 ' (264 mm)

6 NAILERS

MATERIAL:

*Oil canning can

___ 24 Ga. (.65 mm) Galv. Steel*

occur on larger face

.040" (T01 mm) Alum.*

heights. Recommend
.050" (1.27 mm) or .063"

___ .050" (1.27 mm) Alum.

(1.60 mm) for face
heights above

8K" (210 mm).

___ .063" (1.60 mm) Alum.

OTHER

Color:

Finish:

Fabrication will proceed only after receipt of

signed print approval.

Print Approval:

Architect and/or contractor shall verify all
dimensions, sizes and quantities. All
products to be installed in strict accordance

with Flex's printed instructions.

Approved by:

Date:

_____

QUANTITIES:

Lineal Feet 12'-0" (3.65 m) Lengths

. Outside Miter(s) @ (_________ °)

. Inside Miter(s) @ (_________°)

. Right Endcap(s)

. Left Endcap(s)

, Right Endwall Flashing(s)

Left Endwall Flashing(s)

. Overflow Scupper(s) Style_

, Spillout Scupper(s) Style_______

Downspout

Scupper(s)

Style.

(_____ X______ ) Size

A: Tapered 1 1/2" (38 mm) Drop

B; Flat

PROJECT:

ARCHITECT:

ROOFING CONTRACTOR:

REPRESENTATIVE/DISTRIBUTOR:

Customer Service:

Phone: 800-969^0108
Fax:610-916-9501

DATE: 12/13/10
DRN BY: JJC

CKD BY: SAK

SHT# OF

DWG# 28010-11348

p: 800-969-0108

f: 610-916-9501

print approval

45

Advertising