Dangert, Operating procedures – Sears Craftsman 919.153110 User Manual

Page 8

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Grounding Instructions

WARNING

1

IMPROPER GROUNDING CAN RESULT IN
ELECTRICAL SHOCK. IN THE EVENT OF A

SHORT CIRCUIT, GROUNDING REDUCES
THE RISK OF SHOCK BY PROVIDING AN
ESCAPE WIRE FOR THE ELECTRIC CUR­
RENT. THIS AIR COMPRESSOR MUST BE

PROPERLY GROUNDED.

1. The air compressor is equipped with a cord having a

grounding wire with an appropriate grounding plug.
The plug must be used with an outlet that has been
installed and grounded in accordance with all local
codes and ordinances. The outlet must have the

same configuration as the plug. DO NOT USE AN
ADAPTER.

If these grounding instructions are not completely under­

stood, or if in doubt as to whether the compressor is
properly grounded, have the installation checked by a
qualified electrician.

PLUG

White

Wire

Terminal

2. Do not modify the plug that has been provided. If it

does not fit the available outlet, the correct outlet
should be installed by a qualified electrician.

3. Inspect the plug and cord before each use. Do not use

if there are signs of damage.

^DANGERT

RISK OF ELECTRICAL SHOCK. IF REPAIR­
ING OR REPLACING CORD OR PLUG, THE

GROUNDING WIRE MUST BE KEPT SEPA­
RATE

FROM

THE

CURRENT-CARRYING

WIRES. NEVER CONNECT THE GROUND­
ING WIRE TO A FLAT BLADE PLUG TER­
MINAL.

(THE

GROUNDING

WIRE

HAS

INSULATION WITH AN OUTER SURFACE

THAT IS GREEN - WITH OR WITHOUT YEL­

LOW STRIPES.)

Break-In Procedures

This procedure is required only once, before the air com­
pressor is put into service.

1. Set the pressure switch OFF/AUTO lever to the “OFF”

position.

2. Plug the power cord into the correct branch circuit

receptacle.

3. Turn the regulator clockwise, opening it fully, to pre­

vent air pressure build-up in the tank.

4. Move the OFF/AUTO lever to “AUTO”. The compres­

sor will start.

5. Run the compressor for 15 minutes. Make sure the

regulator is open and there is no tank pressure build­
up.

6. After 15 minutes, close the regulator by turning it

counter-clockwise. The air tank will fill to cut-out pres­
sure and then the motor will stop.

Refer to Operating Procedures.

OPERATING PROCEDURES

1. Before attaching air hose or accessories, make sure

the OFF/AUTO lever is set to “OFF” and the air

regulator is closed. (Close it by turning it counter­

clockwise.)

2. Attach hose and accessories.

WARNING

]

TOO MUCH AIR PRESSURE CREATES A
HAZARDOUS RISK OF BURSTING. CARE­
FULLY FOLLOW STEPS 3 AND 5 EACH TIME

THE CC.MPOESSCR IS USED.

3. Check the manufacturer's maximum pressure rating

for air tools and accessories. The regulator outlet

pressure must never exceed the maximum pressure
rating.

4. Turn the OFF/AUTO lever to “AUTO” and allow tank

pressure to build. Motor will stop when tank pressure
reaches “cut-out” pressure.

5. Open the regulator by turning it clockwise. Adjust the

regulator to the correct pressure setting. Your com­
pressor is ready for use.