(Dry,Heat,Fan) Mode Lights:

Upon selecting a mode, a solid green light (window)
illuminates adjacent to the model selected. Under the
"Dry” and "Heat" mode (only) this light also serves to
identify the operational status of the selected

(compressor/heater) program, (see below)

Dry:

A "solid" green light indicates the compressor cycled "on"
and is operational.
A "flashing" green light indicates the compressor cycled

"off' and is non-operational. The fan motor will continue

to operate (flashing green light condition) even after the

compressor has cycled off. This is a normal condition.

Heat:

A "solid" green light indicates the heating element cycled
"on" and is operational. A "flashing" green light
Indicates the heating element cycled "off". Both heater

and fan motor will not be operational during this (flashing
greet! ''Qht) condition.

Fan Mode:
Since there are no controlled settings/options in this

mode, other than fan speed, (high/low) the solid green

light remains on at ail times until the mode is changed

and/or the unit is switched off.

Dry Level Mode Lights:--------------------------------------------- ---

(Continuous, 50%, 60%, 70%, 807o):

A solid green light (window) illuminates adjacent to the
RH% level selected.

Fan Speed Selection:

—--------------------------------

Two fan speeds are available in all operating modes,
"High/Low" identified by a solid green light (window)

adjacent to the mode selected.

Water Full Flashing Light/Audible Alarm:

Dry Mode:

The water full light flashes continuously and an audible

alarm will sound (8 beeps) to notify you when the water

tank is full and/or is not properly positioned inside the

cabinet. The dehumidifier will cease (stop) all operation
automatically, during this condition, (This is a safety
feature.)

Heat & Fan Mode:

The water full light and audible alarm operate in the same

basic manner described in the "DRY" mode (above).

However, the significant difference being both the "Heater

& Fan" will continue to operate under a (full water lank)
flashing light condition. Since no dehumidifylng occurs
during these modes. However, switching back to the
"DRY" mode will immediately stop any dehumidifying
operation.