Gitïunding [nstriætkins, À danger – Sears 919.15412 User Manual

Page 8

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Gitïunding [nstriætkins

WARNING

1

IMPROPER GROUNDING CAN RESULT W
ELECTRICAL SHOCK. IN THE EVENT OP A

SHORT CIRCUIT, QROUNOINQ BCDUCES
THE RISK OF SHOCK BY PROVIDING AN
ESCAPE WIRE FOR THE ELECTRIC CUR­
RENT. THIS AIR COMPRESSOR MUST BE

PROPERLY GROUNDED.

1 The air compressor is equipped with a corti having a

grounding wire with an appropriate grounding plug.
The plug must be used with an ouiiit that has been

inslaJled artd grounded in accordane» wHh all local

codes and ordinances. The outlet must have the
sams configuration as the plug. DO NOT USE AN
ADAPTER,

2. Do not modify the plug that has been provided. If it

does not lit the available outlet, the correct outlet
should be instated by a qualified eiectrician

3 Inspect the plug and cord before each use. Do not use

If there are signs of damage,

À DANGER

RISK OF ELECTRICAL SHOCK. IF REPAIR­
ING OR REPLACING CORD OR PLUG, THE

GROUNDING WIRE MUST BE KEPT SEPA­
RATE FROM THE CURRENT-CARRYING

WIRES. NEVER CONNECT THE GROUND­
ING WIRE TO A FUT BLADE PLUG TER­
MINAL. (THE GROUNDING WIRE HAS

INSULATION WITH AN OUTER SURFACE

THAT IS GREEN - WITH OR WITHOUT YEL­

LOW STRIPES.)

If these grounding instructions are not completely
understood, or If In doubt as to whether the compressor
is properly grounded, have the installation chected by a

qualified electrician.

Ptug

Ground

WWW

Wire

Ouilfti

120 volts, t5 amps

Break-tn ProcBdunas

CAUTION

Serious damage may result if the following

braak-In Inatructrons art not closely

followed.

This procedure is only required the first lime the air com­

pressor is put into service.

1. Set the presffljre switch OFF/AÜTO ieverto the ‘OFF

position.

Z Plug the power cord Into the correct branch circuit

receptacle,

3 Tlirrt the regulator clockwise, opening it fully, to pre­

vent air presBUf© build-up in the tank.

4. Move the OFF.iAUTO lever to "AUTO“. The compres­

sor will start

5 Run the compressor for 10 minutes. Make sure the

regulator Is open and there is no tank pressure build­

up,

6 After 10 minutes, dose th#

regulator

by turning it

counter-clockwise- The air

tark

will fill to cut- out pres­

sure arid ifan the nxitor win stop

BDrv'isjr)i liaise

wr'CiTAi IIMU rtÌLA#BL/Urtli9

1. Before attaching air hose or accessories, make sura

the OFF/AUTO lever is set to “OFF" and the air

rggglator Is dosed. (Cioaa it by turning It counter­
clockwise.)

2. Attach hose and accessories.

WARNING

]

TOO MUCH AIR PRESSURE CREATES A
HAZARDOUS RISK OF BURSTING. CARE­
FULLY FOLLOW STEPS 3 AND S EACH TIME

THE COMPRESSOR i$ USED.

COMPRESSED AIR FROM THE OUTFITMAY
CONTAIN WATER CONDENSATION. DO
NOT SPRAY UNFILTEREO AIR AT AN ITEM
THAT COULD BE DAMAGED. SOME AIR
OPERATED TOOLS OR DEVICES MAY
REQUIRE FILTERED AIR. READ THE
INSTRUCTIONS FOR THE AIR TOOL OR
DEVICE.

3. Chock ttia manufacturer's maximum prassi«'e rating

for air tools and acoassories. The regulator outlet
prasauw must navar axesed the maximum pressure
rating.

Advertising