Troubleshooting – Sears QUIET COMFORT 758.14417 User Manual

Page 13

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Troubleshooting

Trouble

Probable Cause

Remedy

Unit will not run and no

control panel lights are

illuminated.

• No Power.

• Check 120 volt power

source.

Unit will not shut off.

• Float retainer is positioned

in “Manual Dryout” position.

• Slide float retainer down to

normal operation mode.

Refer to “Manual Dryout”

section on page 7.

• Float is not free.

• Free float from obstruction.

Unit will not dry out

completely.

• Float is positioned in

normal operation mode.

• This is normal. A small

amount of water remains in

the cabinet after Fill Lights

come on. Position float
retainer in "Manual Dryout”
position to completely dry out.
See page 7.

Bottles continue to empty.

• Air is entering water bottles.

• Check “E-Z-Fill Side-Caps”

and valve assembly caps to
ensure tightness.

• Check for leak in water bottles.
• Ensure gaskets for “E-Z-Fill

Side Caps” are in place.

Neither bottle emptying.

• Bottle cap plunger missing

post in bottom of cabinet

• Check orientation of bottles.

Reposition so that bottle cap

plunger (stem) is depressed
by post in bottom of cabinet.

• Dirty filters

• Change to fresh new filters.

(42-14911)

Left bottle not emptying.

• Right bottle contains water

• The humidifier is designed so

the right bottle empties first.

Continue to run until both fill
lights come on.

Fill Indicators turn on before

bottles are empty.

Note: There may be a little

water still in bottle when Fill

indicator is illuminated. This
is normal.

• Unit is not set up on a level

surface. (Float will not
sense water at the rear of

the cabinet.)

• Position unit level. (Some

carpet padding may allow
unit to sit lower in front than
rear with the additional

weight of water bottles in
the front of the cabinet.

Install caster pads under

front casters. (See page 4).

CAUTION: Use only 42-14900 EPA Registered Bacteriostat available from Sears Retail
store.
Use of other water treatment products may damage the filter elements.
Under no circumstances should you use water treatment products designed for Roto

belt or Ultrasonic humidifiers.

13