Calculating charge time

The Chart Method

Use the following table to more accurately determine

the time it will take to bring a battery to full charge.

First, identify where your battery fits into the chart.

• Smali batteries — motorcycles, garden tractors, etc.

— are usually rated in Ampere Hours

(AH).

For

example; 6 to 12 AH, or 12 to 32 AH.

• Batteries

In

cars and smaller trucks are usually rated

in Reserve Capacity

(RC),

Cold-Cranking Amps

(CCA),

or both.

• Marine, or deep-cycle batteries are usually rated in

Reserve Capacity

(RC).

• NR

means that the charger setting is NOT

RECOMMENED.

Find your battery’s rating on the chart to the right
note the charge time given for each charger settir

The times given are for batteries with a

50-percei

charge

prior to recharging. Add more time for sev

discharged batteries.

BATTERY SIZE/RATING

CHARGE RATE/CHARGING IIME • HOURS

2 AMP

10 AMP

SMALL
BATTERIES

Motorcycle, garden

tractor, etc.

6-12 AH

2-4

NR

12-32 AH

4-10

NR

CARДRUCKS

200-315 CCA

40 - 60 RC

11 -14

2 - 27e

315-550 CCA

60 - 85 RC

14-18

2^/8 - 3%

550 -1000 CCA

85 -190 RC

1 8 - 3 5

3 % - 7

MARINE/DEEP CYCLE

80 RC

18

ЗУ

2

140 RC

27

5Уг

160 RC

30

6

180 RC

33

7

The Hydrometer or Electronic Method

To find the time needed to fully charge your battery,
determine the battery’s charge level with a hydrometer
or electronic Percent-of-Charge Tester. The following
table will help you convert hydrometer readings to

percent of charge values.

SPECIFIC

GRAVITY

PERCENT

OF CHARGE

PERCENT OF

CHARGE NEEDED

1.265

100%

0%

1.225

75%

25%

1.155

25%

75%

1.120

0%

100%

When you know the percent of charge and the Amp

Hour (AH) rating of your battery, you can calculate the

approximate time needed to bring your battery to a full
charge.

To

convert

Reserve Capacity to Amp Hours, divide

Reserve Capacity by 2, and add 16:

Amp Hours = Reserve Capacity -i- 16

2

To calculate time needed for a charge:

Find the percent of

charge needed.

(A battery at

50 percent charge that will be charged to 100

percent needs another 50 percent (.50).

Multiply the Amp Hour rating by the charge
needed (.50) and divide by the charger setting
(2 or 10 amps).

Multiply the result by 1.25 and you’ll have the
approximate time needed, in hours, to bring the
battery to full charge.

Add one additional hour for a deep-cycle battery.

Example:

Amp Hour Rating x charge needed x 1.25

Charger Setting

hours
of
charge

100 (AH Ratinal

X

.50 (charge needed) x 1.25 = 6.25

10 (Charger Setting)

hours

100

X

.50 = 5

X

1.25 = 6.25

10

You would need to charge your 100-Ampere Hour Bat­
tery for approximately 6-1 /4 hours at the 10-Amp charge

rate using the above example.

8