ROUGH-IN INSTRUCTIONS

NOTE: For proper combustion, make sure units are
level, front to back and side to side.

FIGURE 5A - DRY WALL

FIGURE 5B - PLASTER WALL

FIGURE 1

ROUGH-IN
DIMENSIONS

Dry-Wall

B-W Type Vent

Front
Panel

Screw

Plaster
Ground

Plaster

B-W Type Vent

Screw

Front
Panel

Plaster
Ground

STEP 4.Remove double ceiling plate between studs.

Install one ceiling plate spacer across the cut out
in ceiling plate. Install vent pipe into position,
be sure to lock bottom of vent pipe into the base
plate. Nail second ceiling plate spacer in place.
(See Figure C, Page 6).

STEP 5.If the vent continues through additional stories

within the 2x4-stud space, then fire-stop-spacers
must be installed at the second and subsequent
ceiling levels. See Figure D.

FIGURE D

Installation of B-W gas
vent for each subsequent
ceiling or floor level
of multi-story
buildings

Firestop spacers
supplied by
manufacturer of
B-W gas vent

Plate cut away to
provide passage of
B-W gas vent

Nail firestop
spacer securely

VENT INSTALLATION

2 FT. MIN.

LISTED
VENT TOP

STORM COLLAR

ROOF
FLASHING

OVAL TO
ROUND ADAPTER

CEILING PLATE
SPACERS

12 FT.
MIN.

LISTED “BW”
VENT PIPE

BASE PLATE

HEADER PLATE

2 X 4 WALL
STUDS

CEILING
PLATE
SPACER
LANCES

Page 7

FIGURE 2 - VENT INSTALLATION

*65-3/4”

* This
measurement
must be
taken from
top of
floor
plate

4”

4”

14-1/4”
Min.
14-1/2” Max.

Advertising