Majestic fireplaces, Odsr series "a, Chase installation – Vermont Casting ODSR36A User Manual

Page 5

Advertising
background image

5

Majestic Fireplaces

®

ODSR Series "A"

20006811

FP554

BR/BC

Combo of IWF261 AND IWF265

11/10/97

Chase Installation

Insulation methods shown are optional
for cold climate, not a requirement for
unit operation.

FP554

Fig. 3 Fireplace and chase parts identification.

Termination Cap

Storm Collar

Pan Flashing

Draftstop

Batt Insulation

(cut out around

fiestop)

Firestop

Ceiling Level

Nailing Flange

Gas Line Access

(both sides)

Electrical Access

Outside Air Cover Plate

Metal Safety Strips

(1, 2 or 3 pieces)

Firebox

Grate

Screen

Gas Line Knockout

(both sides)

Damper Control

Surround

Standoff

FP1001

fireplace setting

1/4/00 djt

10'

(3m)

Min.

6'4"

(1.9m)

Min.

NOTE: If the fireplace is a
freestanding unit, it must be
located a minimum of 10'
(3m) from the opening of
the firebox to a combustible
structure.
A minimum height of 6'4"
(1.9m) measured from the
base of the firebox to the bot-
tom of the termination cap is
permitted.

FP1001

Fig. 4 Freestanding installation.