3 module level security configuration, Module level security configuration -7, Module level security configuration screen -7 – Cabletron Systems 2M46 User Manual

Page 91: Or details, refer to, Section 3.3

Advertising
background image

Module Level Security Configuration

Local Management Supplement

3-7

3.3

MODULE LEVEL SECURITY CONFIGURATION

The Module Level Security Configuration screen,

Figure 3-3

, is used to

set the state of security according to connector. All repeater ports on a
connector can be set to receive all frames (NonSecure state), lock on the
source address of the next frame received (LockOnNext) or the source
address of the last frame received (LockedOnAddr). When either of the
last two options are set, the switch can be set to enable or disable the
reception of frames and send or not send traps when an intruder is
detected.

To access the Module Level Security Configuration screen, use the arrow
keys to highlight the MODULE LEVEL SECURITY
CONFIGURATION
menu item on the Repeater Configuration Menu
screen and press ENTER. The Module Level Security Configuration
screen displays.

Figure 3-3

Module Level Security Configuration Screen

Connector Security State

Action On Intruder

1 [LockOnNext]

[DisablePort] [SendTrap]

2 [PortMismatch]
3 [NonSecure]
4 [LockedOnAddr]

[DisablePort] [SendTrap]

SAVE EXIT RETURN

2276_112w