Cleveland Standard Features

5 psi Operating Pressure in cooking compartments

Mechanical interlock prevents unlatching door while compartment
is pressurized

Timers, one per compartment, are mechanical style with
audible signal

Thermostatic Trap vents cooking compartment automatically

Steam Inlet Valves and Exhaust Valves interlocked for
synchronous action

8 psi Compartment Safety Valve

Capacity per compartment for eight, 12” x 20” x 2 1/2” deep
Cafeteria Pans, or four, 18” x 26” Bun Pans

Heavy Duty, free floating, cast aluminum compartment doors

Compartment Door Hinges have adjustable hinge pins and
self-lubricating bushings

Door Gasket replaceable without tools

Pressure Gauge for compartment operating pressure

Compartment Slide Racks are removable without tools, for
easy cleaning

Type 430 Stainless Steel: external enclosure, Table Top and
eight gage plate cooking compartments

Modular Cabinet Base with Hinged Doors

High efficiency Electric Steam Generator with Automatic
Water Fill on start-up

Automatic Water Level Control System with Low Water Power
Cut-off Circuit

Steam Generator equipped with High-limit Pressure Safety
Switch and Safety Valve

Automatic Steam Generator (boiler) Blowdown allows intermittent
control, complete with additional Manual Drain Valve

Steam Generator Pressure Gauge

6” Stainless Steel Legs with level adjustment and flanged feet

Single Cold Water Connection (no hot water required)

❐ Secondary Low Water Cut-Off, factory installed (CALE)

(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN.
MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash.
DC)

Standard Voltage 208-240 volts, 60 hz, single phase, three
wire

All Major Components are serviceable from the front of unit

Options & Accessories

❐ Automatic Steam Inlet and Exhaust Operation (AT-2):

includes 60 minute Automatic Timers and Manual Bypass

Shall be _____ Compartments, CLEVELAND, Pressure Steamer, Model

PEM- _____

-

_____

,

Electric Steam Generator, _____

kw,

_____ volts, _____ ph, three wire. Each Cooking Compartment equipped

with: 60 Minute Timer; Heavy-duty, free floating Door with Safety

Interlock; and synchronous operating Steam Inlet and Exhaust/Drain

Valves. Solid State Controls operate Water Level and Steam

Generator (boiler) Safety Functions. Automatic Steam Generator (boil-

er) Blowdown with additional Manual Drain Valve.

❐ 15 psi for Kettle Operation, includes Power Take-Off (PTO)
❐ Kettle Interconnecting Kit (IMK)
❐ Stainless Steel base Frame (FSS)
❐ Stainless Steel gas flue cover, insulated (SSF)
❐ Special compartment Slide Racks
❐ 12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep
❐ Intermediate Pull-Out Shelf (POS)
❐ Spray Head with flexible Hose (SH)
❐ Voltages, other than standard
❐ Water Filters
❐ Correctional Packages

Short Form Specifications

PRESSURE STEAMERS

2 OR 3 COMPARTMENTS, CABINET MOUNTED
ELECTRIC STEAM GENERATOR
24, 36 OR 48 KW, 36” WIDE CABINET BASE

MODELS:

2 Compartments

3 Compartments

PEM-24-2

PEM-24-3

PEM-36-2

PEM-36-3

PEM-48-2

PEM-48-3

SECT.

VI

PAGE

1

0707

Advertising
This manual is related to the following products: