When this occurs, the АТС will shut the cold wa­
ter valve off for a brief period of time and turn it

back on to maintain a proper temperature flow.
Rinse fills are not temperature controlled unless

Warm Rinse is selected. During activation, the

indicator light is only ON when the board is con­

trolling water temperatures.

The following chart (Figure 8-3) depicts the

philosophy on how the Automatic Tempera­

ture Control Board operates. Note, the Ther­

mistor Temp represents the temperature
sensed by the thermistor in the water valve.

The outputs are indicative of the board send­

ing voltage to the water valve solenoids.

You will note in the following table, the only

combinations where the temperature control
board is active (BOLD) are Warm and Cold

with the temperature control selector in the

ON position. When Cold is selected and the

temperature sensed by the thermistor is too

low at the valve, the Hot valve will be activated.

When Warm is selected and the temperature

sensed by the thermistor is too cool, the Cold
valve will be shut off.

Analog Automatic Temperature Control (АТС) Truth table:

Water Temp

Selections

АТС

Selector

Thermistor

Temp

Hot Valve

Output

Cold Valve

Output

Indicator

Light

Hot

Off

Low

On

Off

Off

Warm

Off

Low

On

On

Off

Cold

Off

Low

Off

On

Off

Hot

Off

High

On

Off

Off

Warm

Off

High

On

On

Off

Cold

Off

High

Off

On

Off

Hot

On

Low

On

Off

Off

Warm

On

Low

On

Off

On

Cold

On

Low

On

On

On

Hot

On

High

On

Off

Off

Warm

On

High

On

On

On

Cold

On

High

Off

On

On

Figure 8-3

Analog Temperature Board Tests

In order to test the board for proper function,

we need to monitor incoming and outgoing

signals to and from the temperature control
board. The chart shown on the next page pro­
vides a listing of the eleven terminal pin con­
nections (Figure 8-4) of the board, their source
or function, and identifies outputs/inputs
(Figure 8-5).

GY PK PU

GY BR

BK

YL OR

BU

PLUG

WH

47

4

3

47

51

12

35

13

11

7N

11 10 9 8 7 6 5 4 3 2 1

WIRE INSERTION SIDE

SL282TIF

Figure 8-4

16009485-01

©1999 Maytag Appliances Sales Company

Section 8. Electrical Components & Testing

8-5

Advertising