REMOVING AND REPLACING

NEEDLE PLATE

• Raise presser foot
• Raise needle to highest position.

Open slide plate. Place thumb under right

side of needle plate, lift it up and withdraw it

to right.

• Replace needle plate under clamping pin A,

push it gently to the left and press down
until it snaps into place.

NEEDLE PLATE RAISING SHIM

(with model 9518)

1. To insert, open the slide plate, place the

raising shim in the slideway and close the
slide plate as shown.

• The raising shim will slide into place under

the needle plate, raising it above the feed.

2. To remove, open the slide plate and pull

the raising shim forward in the slideway.

ATTACHING SNAP-IN FEED COVER

(with model 9618)

• Raise presser foot.

Raise needle to highest position by turning

hand wheel

toward you.

Open slide plate.

Slide snap-in feed cover away from you

over needle plate until points B and C are
positioned directly over holes in needle pla­
te as illustrated. Snap in point B. Then push
point C in toward point B until It snaps into
place. Close slide plate. To remove, open

slide plate then simply lift up front edge of

feed cover.