INSTALLING THE NEW POWER SUPPLY:

1: Strip the red and black replacement power supply

wires ¼” from ends.

2: Insert the high voltage wires through the holes in the

enhancement face (Fig. 10-A). Make sure the wires

do not kink or have twists in them.

3: Mount the new power supply module to the

enhancement module using the four screws removed

earlier (Fig. 10-B).

NOTE: Make sure the green ground wire runs down

the groove in the enhancement module face behind

the power supply enclosure.

4: Reconnect the green ground wire to the enhancement

module (Fig. 11).

5: Crimp the new ¼” quick disconnect terminal onto the

red replacement power supply wire and connect to the

ionization array (Fig. 12). This may require the use

of needle-nose pliers.

Fig. 10-A

Fig. 11

Fig. 10-B

Fig. 12

8: Remove the power supply module from the enhancement

module by unscrewing the four Phillips head screws (Fig. 9).

You are now ready to install the new power supply.

UNIT OPERATION HAZARD
Failure to follow this caution may result in equipment

damage or improper operation.
Improper wiring will reduce unit performance.

CAUTION

Fig. 9

2 Screws

2 Screws