Peration, Aster, Lave – Chauvet SNAPSHOT LED PAR 38 TRI-B User Manual

Page 13: Menu map, Dmx operation, Master/slave

Advertising
background image


4. Operating Instructions

13

9/22/2009 11:10 AM

Menu Map

M

AIN

F

UNCTION

S

UB

-F

UNCTION

S

ELECTION

S

UB

-S

ELECTION

I

NSTRUCTION

7 Color Switching

-

Select between 2 switching and 2 fading
built-in programs

7 Color fading

3 Color Switching

3 Color Fading

7 Color sound active

Use the Audio Adjustment
Knob located on the back
of the fixture

Select between 2 sound active programs

3 Color sound active

~

-

-

Select 3-channel DMX mode (RGB control)

~

-

-

Select 7-channel DMX mode: RGB, macros,
run speed, strobe, automatic/sound, dimmer

Red

-

Select between 7 static colors. The display
will read ~

. The colors that each of

these represent are indicated to the left.

Green

Blue

Cyan

Magenta

Yellow

White

~

(default range is

)

-

This is the speed range for the 4 switching
and fading built-in programs

Red

~

Combine red, green, and blue to create a
custom, static, color

Green

Blue

DMX Operation


This is the operating mode which will allow for control with an external DMX controller. You must set the starting
address for this mode. If this

is your first time using DMX, then it is recommended that you refer to the “DMX

Primer” section in the “Appendix” of this manual.

1.

Press <MENU> until

or

appears on the LED screen.

2.

Press <ENTER>.

3.

Using <UP> and <DOWN>, select the desired DMX address (

~

).

Master/Slave


This is the operating mode which will allow

1 fixture to act as the “master” and control all of the other “slave”

fixtures. You must set both the master and the slave(s) fixtures to the correct mode for this operation.

Master Settings:

1.

Connect the fixtures with DMX cables, as shown in the “Fixture Linking” section.

2.

Use any one of the standalone modes for the master unit. This includes:

,

, and

Slave Settings:

1.

Press <MENU> until

or

appears on the LED screen.

2.

Press <ENTER>.

3.

Using <UP> and <DOWN>, set the DMX address to

.

It is not necessary to set the master fixture as the first fixture in the daisy chain. It may be any fixture
in the daisy chain. For example: fixture 2, 5, 10 or 12, etc.


Only 1 fixture may be set to master.


Do not connect a DMX controller to the daisy chain for this operating mode.

Advertising