Starter rope, E. starter rope – Poulan 1600 User Manual

Page 18

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

£. STARTER ROPE

This is a complicated and potentially hazardous

task.

It is recommended Uiat only a qu^ifled service

dealer perform this repair.

A

warning

Always wear eye protection and gloves when servicing

the starter rope. The recoil spring, located beneath the
pulley, is under tension. If the spring flies out, serious
injur}" can result.

• To repair or replace:

1- Disconnect spark plug wire.

2. Drain all fuel from tank.
3. Remove the two screws and two washers from the

fuel tank. Figure 24. Set fuel tank aside.

4. Removethefivescrewsfrornfanhousing,Figure25.
5. Separate fan housing from shroud about 2 inches.
6. Slide high tension lead grommet from slot in fan

housing. Figure 26,

7. Separate fuel line leaving the connector in the end

attached to the fuel tank. Figure26.

8. Separate the fan housing completely from the

shroud. Figure 26.

9. If the starter rope is not broken, release the spring

tension by pulling about 12 inches of rope from the
pulley and catch the rope in the notch as shown.

Figure30.

jCAUTlON:

} Be sure the tension on the starter

spring is released by rotating the pulley clock-
лу15е —rk with your finger while pushing down

on the pulley ^vith your hand.

10. Remove screw from the starter pulley veiy carefully.

Rotate the pulley clockwise until no spring

tension is felt and carefully lift the pulley out of the
fan housing. Figure 29. Remove the old rope.

11. Move away from the fuel tank with the rope to be

installed. Use amatch and melt both ends of the rope

to prevent fraying.

12.

Pullthemeltedendsthroughathick,cleanrag

while

the rope is still hot to obtain smooth, pointed tips.

Б. Insert one end of the rope through the handle and

secure with a knot.

14. Insert the free end of rope through rope exit hole into

the inside of the fan housing,

15. GuideropeinsidepuUey, then up through the pulley

ratchet side of pulley hole to the outside by pushing
the rope through from the hole on the spring cam side

with a small Phillips screwdriver. Figure 27.

16. Wrap rope counterclockwise Л around pulley

ratchet and tuck loose end back under rope where it

comes out of hole. Leave a 1/4 to 1/2 inch tail laying
flat on the top of the pulley. The rope tail must not
extend beyond the edge of the pulley. Figure 28.

17. Carefully replace pulley in the housing. Be sure the

pulley is aU the way down. Replace washer and screw
and tighten. Figure 29.

18. Turn the puUey clockwise

until all the rope is

wrapped onto the pulley.

19. Pull out the rope by the handle (approximately 12")

and hold the pulley,

20.

Pullthe

12inchslackintheropeintothemsideofthe

fan housing and catch rope in pulley notch. Figure
30.

21. Hold the rope taut and make 2 complete turns of the

pulley counterclockwise

to place tension on

the spring. Continue to hold the pulley to retain

tension.

22. Aligh pulley notch with rope exit hole, release slack

in the rope and puli starter handle to the full extent

of the rope. Releasethepulley and slowly allow the

rope to wind around the pulley.

23. Reverse procedure for re-assembly of fan housing

to shroud.

Figure 24

Figure 25

18

Advertising