Section 1.1- GENERATOR FUNDAMENTALS

WHAT IS A "CCG"?:

The initials “CCG” stand for “computer con­

trolled generator“. Such units are different from

conventional generators in that the performance of

the engine and AC generator are more accurately

matched over a wide range of power needs. The

CCG’s provide greater efficiency of both the engine

and the generator while maintaining electrical out­

put within an acceptable voltage and frequency

band.

CCG units have the ability to operate the engine

over a wide range of speeds, while conventional
generators will deliver correct AC frequency and

voltage only at a fixed rpm. The unit’s electrical
output is fed through an AC-AC converter which
reconstructs electrical waveforms to the correct
output frequency.

Unlike conventional AC generators, the CCG can

match engine speed to load requirements. This
provides several advantages, as follows:

П Smaller engines can be used to produce more

power than on a conventional generator, since
it can be allowed to run at a higher speed.

When the load is reduced, the engine can run

at slower than the usual speeds. This improves

fuel economy and reduces engine noise.

The CCG unit can be operated closer to its peak

power point at all times, because output volt­
age and current are functions of engine speed.

This allows fora much more compact generator
design.

CCG SYSTEM OVERVIEW:

introduction to CCG’s

in the diagram. Operation of the system may be
described briefly as follows:

Figure 10 is a block diagram of the CCG system.

The major elements of the system are represented

1.

The engine is directly coupled to a permanent

magnet type Rotor, so the Rotor runs at the same

speed as the engine.
2. As the Rotor turns. Its magnetic field cuts across

the Stator windings to induce a voltage into the

Stator.

a. The Stator is a 2-phase type with center tap.

b. Stator AC output frequency Is between 336 and
540 Hertz. This corresponds to engine speeds of

2520 to 4050 rpm.

c. The load requires a nominal AC frequency of

60 Hertz. Thus, the generated frequency Is six to

nine times the desired range.

3.

A Frequency Converter changes the high fre­

quency output to a useful frequency, I.e., one that
is compatible with load requirements of about 60
Hertz.

4. A Voltage Detector circuit senses load voltage
and signals a System Control circuit.

5. The System Control circuit establishes the RE­

QUIRED ENGINE SPEED for correct voltage and

delivers an output to an Engine Controller.
6.

The Engine Controller adjusts the engine’s

Throttle to change engine speed and establish the

correct AC output voltage.

7. The following facts should be apparent:

LOAD FREQUENCY IS CONTROLLED BY THE

“FREQUENCY CONVERTER“ DEVICE.

VOLTAGE IS CONTROLLED BY A “SYSTEM

CONTROL“

CIRCUIT

WHICH

CHANGES

EN­

GINE

SPEED

TO

MAINTAIN

A

CONSTANT

VOLTAGE AT VARYING ELECTRICAL LOADS.