Troubleshooting – Generac 7500 User Manual

Page 13

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Generac Portable Products 7500EXL Extended Life Generator

TROUBLESHOOTING

Problem

Cause

Solution

Engine is running, but

no

AC

output Is

available.

1. Circuit breaker is open.

2.

Poor connection or defective cord set.

3.

Connected device is bad.

4.

Fault in generator.

1. Reset circuit breaker.

2.

Check and repair.

3. Connect another device that is in

good condition.

4.

Contact Generac service facility.

Engine runs good but
bogs dow n w hen

loads are connected.

1.

Short circuit in a connected load.

2.

Generator is overloaded.

3.

Engine speed is too slow.

4. Shorted generator circuit.

1. Disconnect shorted electrical load.

2. See “Don’t Overload the Generator”

on page 11.

3. Contact Generac service facility.

4. Contact Generac service facility.

Engine w ill not start;

or starts and runs

rough.

1

. Run/Stop switch set to

“Stop”.

2. Dirty air cleaner.
3. Out of gasoline.

4. Stale gasoline.

5.

Spark plug wire not connected to
spark plug.

6.

Bad spark plug.

7.

Water in gasoline.

8.

Overchoking.

9.

Low oil level.

10.

Excessively rich fuel mixture.

11.

Intake valve stuck open or closed.

12.

Engine has lost compression.

1.

Set switch to

“Run”.

2.

Clean or replace air cleaner.

3.

Fill fuel tank.

4.

Drain gas tank and fill with fresh

fuel.

5.

Connect wire to spark plug.

6.

Replace spark plug.

7.

Drain gas tank; fill with fresh fuel.

8.

Put choke lever at “No Choke”
position.

9.

Fill crankcase to proper level.

10.

Contact Generac service facility.

11.

Contact Generac service facility.

12.

Contact Generac service facility.

Engine shuts dow n

during operation.

1.

Out of gasoline.

2.

Low oil level.

3.

Fault In engine.

1. Fill fuel tank.

2. Fill crankcase to proper level.
3. Contact Generac service facility.

Engine lacks pow er.

1. Load is too high.

2. Dirty air filter.
3. Engine needs to be serviced.

1. See “Don’t Overload the Generator”

on page 11.

2. Replace air filter.
3. Contact Generac service facility.

Engine “hunts” or

falters.

1. Choke is opened too soon.

2. CariDuretor is running too rich or too

lean.

1. Move choke to halfway position till

engine runs smoothly.

2. Contact Generac service facility.

13