i4000 - Quad M-module carrier for VMEbus
User Manual

Version: 1.2

AcQuisition Technology bv
P.O. Box 627, 5340 AP

Page 10 of 25

Oss, The Netherlands

3.2.

C

ONNECTORS

3.2.1. M

OUNTING AN

M-

MODULE

Four M-modules can be fitted on the i4000 carrier board. To plug in a module, position the 2-row 40 pole or
3-row 60-pole M-module interface connector of the module above the 2-row header P1 of the i4000. Then
push the module until the header connector is positioned and press the module with care in its place.

Note:

With 3-row M-modules row C of the M-module interface connector is left unoccupied.

The module should be secured in its position using four screws (M3 * 5mm), refer to figure 1 for the positions
of the mounting screws.

Figure 1 M-module mounting screws

Module component side

20

1

Module component side

20

1

Module component side

20

1

Module component side

20

1

Row a b c