Measuring flow rate, 28 repair – Nespresso Essenza FS EF 474 User Manual

Page 28

Advertising
background image

28

Repair

Service Manual EF 473 / EF 474

en

Version 1.0

Measuring flow rate

Procedure:

1. Fill water tank.
2. Insert pressure plug in capsule inlet.
3. Press down closing handle lightly till

pressure plug fits in capsule cage.

4. Pull off holding device. The pressure plug

clamps itself to the capsule cage.

5. Position measuring beaker underneath

exit tube of pressure plug.

6. Switch on machine.
7. Press button "large cup" after heating-up.
8. Open valve fully till water begins to flow.
9. Close valve until 12 bar are indicated.

)

The manometer must be observed
continuously and the pressure
regulated using the valve if
necessary. With increasing
temperature the pressure also
increases, if necessary readjust the
pressure to 12 bar.

10. Perform measurement for approx. 30 sec.

11. There must be at least 60-120 ml water in

the measuring beaker.

Notice:
- With a flow of < 60 ml the pump is defective

or there is a leak in the system.

- Large fluctuations in the pressure gauge

readings (± 4 bar) during measurement are
indicative of a defective pump.

1

2

3

4

5

8

9

7

6

Advertising
This manual is related to the following products: