Setup -- furnace – Carrier Infinity SYSTXCCUID01- B  User Manual

Page 9

Advertising
background image

9

Reset Factory Defaults:
Program Schedule:

S

Yes/No to reset back to Energy Star default Time and Temp
schedules.

User Settings:

S

Yes/No to reset the user settings in the Advanced Setup to
factory default settings.

Install Settings:

S

Yes/No to reset install settings in Install/Service menus to factory
default settings.

Last 10 System Events:

S

Yes/No to reset last 10 events under Service Info menu.

Setup -- Furnace

Upon a first time start--up of the Infinity Control, the furnace DIP
switch settings will be copied to the furnace setup menu. Any

changes can then be made from the Infinity Control.
Airflow:

S

COMFORT (default)

S

EFFICIENCY

Selects the airflow of the furnace when heating. EFFICIENCY is
the airflow used to meet specified ratings, COMFORT is a

decreased airflow used to increase the output air temperature and

provide increased comfort.
AC Airflow:

S

COMFORT (default) -- cooling airflow is varied depending on
humidity and temperature demands settings. This selection
enables the full dehumidify and comfort capabilities of the
system. When COMFORT is not selected, the unit will not run
reduced airflows for dehumidification.

S

EFFICIENCY -- fixed airflow used to achieve specified ratings --
no dehumidification airflow reduction. This is nominally 350
CFM/ton, but will vary if a 2--stage outdoor unit is used.

S

MAXIMUM -- 400 CFM/ton. No dehumidification airflow
reduction.

Dehum Airflow:

S

NORMAL (factory default) -- When equipment is running to
dehumidify, the airflow is allowed to adjust to a minimum to
satisfy the dehumidification call.

S

HIGH -- Minimum airflow during the dehumidify mode is
increased to reduce duct and register sweating.

Low Heat Rise

S

ON

S

OFF (default)

Set to ON if the system contains a bypass humidifier. The ON
setting will increase the furnace low heat airflow.
Staging

S

SYSTEM (default)

S

LOW

S

HIGH

S

FURNACE

NOTE: Controls the staging of the furnace. More staging options
will be available if furnace is capable of more stages. SYSTEM
setting will allow the Infinity Control to determine furnace staging.
LOW will only run the low stage of furnace heat. HIGH will only
run the high stage of furnace heat. FURNACE will allow the
furnace algorithm to control staging.

G Terminal
This setup option selects desired operation when the R--G circuit

changes state on the furnace control board depending on setup.

S

DISABLED (Default)

S

FAN -- turns on fan to selected fan speed when G terminal is
energized. See Fig. 26.

S

FAN SPEED -- select Low, Med, High for all zones when G
terminal is energized

S

SHUTDOWN -- shuts off fan and equipment when initiated.
This function is not intended for emergency fire shutdown. It
may be activated by a dry contact from an external device such
as a float switch or a relay. User Interface displays SYSTEM
MALFUNCTION on screen and registers G terminal shutdown
event in Last 10 System Events. See Fig. 27.

R

G

FE Fan Coil or
Variable Speed Furnace

A07114

Fig. 26 -- G Input Wiring for Blower Operation

R

G

FE Fan Coil or
Variable Speed Furnace

A07115

Fig. 27 -- G Input Wiring for System Shutdown

with (--B) Infinityt Control (Contact type selectable;

Normally Closed (default) or Normally Open)

High Stage Timer
Minimum amount of time low stage must operate before high stage

is activated. Ten to 60 minutes. 10 = default
A demand of 5_F / 3_C or more will override the staging timer.
Off Delay

S

90 seconds

S

120 seconds (default)

S

150 seconds

S

180 seconds

Amount of time the blower will continue to run after heating has

shut off.

CCUI

D

01

--

B

Advertising