Menu screen functions, Time of day, Day of week – 3M 30 User Manual

Page 9: Swing

Advertising
background image

PG

8

PG

8

PG

9

MENU Screen Functions

Press MENU to bring up MENU screen.

TIME of DAY

Touch the left (down) or right (up) arrows next to the time display to set the current time (1 minute per

touch). Touch and hold the arrow for fast time set (15 minute jumps).

DAY of Week

Touch DAY area to select present day.

SWING

(HVAC cycling rate) This feature allows you to set the desired variance in temperature

between the 3M-30 setting and the room temperature required before the heating or cooling system

will turn on—from 0.5° to 2.0° F (.25° to 1° C). For example, if SWING is set to 2.0° F and the 3M-

30 is set to 70°F Target Temperature, the heat cycle will start when room temperature drops to 68°F.

Similarly, the cooling system will start when the room temperature increases to 72°F. The HVAC then

runs and will shut off at the Target Temperature.

To set

SWING:

Touch SWING.

Touch the left/right arrows to set the SWING from 0.5° to 2.0° F.

The HVAC will run more frequently at .5°F and less at 2°F. Default is 1°F.

Touch HOME to return to the MENU screen.

Advertising