COPY

This will copy one day’s programming to the next day. Press

COPY

once. The information for the

current day will be copied to the next day which will appear on the screen. Holding down COPY for

over 3 seconds will copy to all 7 days.
• Press

to store your settings.

Keypad Functions

TIME

Press

(time backward) or

(time forward) to set the current time. Press and hold the arrow

for fast time set (15 minute step).

DAY

Press

(SET DAY) to set the day of the week. The day of the week display advances (initially SU

for Sunday). Press

again to step throught the days of the week until the correct day is displayed.

SWING

( HVAC cycling rate)

This feature allows you to set the desired variance in temperature between the 3M-22 setting and

the room temperature required before the heating or cooling system will turn on—from 0.5° to 2.0° F

(.25° to 1° C). For example, if HVAC CYCLING is set to 2.0° F and the 3M-22 is set to 70°F, the heat

cycle will start when room temperature drops to 68°F. Similarly, the cooling system will start when

the room temperature increases to 72°F. The HVAC then runs and will shut off at the target.