Pentax me super User Manual

Page 10

Advertising
background image

23903

Page 9 of 32

If the conductivity of Switch board (A318) was good, install Top cover

assy. (A300).

The point of installation is the same as 23900 ME.

Cover frame (A131)

Top cover retainer screw A (A333)

2pcs.

Top cover retainer screw B (A334)
Top cover retainer screw C (A332)

2pcs.

Top cover retainer screw D (A335)

After installed, check the function of LED by changing the shutter
dial.

21.

ASA ring assy. (0-D11-01), Rewinding knob assy. (0-D6)

ASA ring assy. (0-D11-01)
Washer (D21)
Nut (D15)

After installed, check the function of click of ASA ring assy. (0-D11-

01). and the LED indication.

At 1/4X, 1/2X, 2X and 4X except 1X, EF red LED must be flickering. If

not, check the clearance of ElF switch contact piece (A44) and lead

wires and/or adjust ElF index plate (D23) assembled in ASA ring assy.

(0-D11-01), as shown below.

0-D11-01

D23

Fix D23 as pushing to the

arrowed

direction

Rewinding knob assy. (0-D6)

22.

Winding lever assy. (0-C69)

Winding lever friction spring (C7-01)
Winding lever assy. (O-C69)
Winding lever nut (C8)

left handed

23600K0C134-A-2

Cover screw (C139-01)

left handed

23600K-C135-A

Check the function of shutter and winding.

23.

Check the shutter button stroke Shutter dial Bulb

a.

When pushed the shutter button deeper than 0. 2mm from the original

position, LED should be turned ON before release the shutter.

Main switch ON position

b.

After released 1st curtain, the shutter button can goes down
0. 1 - 0.5mm.

Advertising