Freezer system and adjustment – Continental Refrigerator Refrigerators and Freezers User Manual

Page 17

Advertising
background image

compressor is not operating during an off-cycle. Do not set the thermostat too cold
where the cabinet temperature will fall below 2`c because the evaporator will
become blocked by ice since the compressor off-cycle will be considerably
shortened. This will result in loss of product stored within the cabinet and require
service to defrost the evaporator and re-adjust the thermostat.


FIGURE

7

REFRIGERATOR AND FREEZER THERMOSTAT

FREEZER SYSTEM AND ADJUSTMENT

All self-contained standard freezers and low-temperature freezers are designed
and factory set to maintain an average cabinet temperature of -20`c and -28`c
respectively. All freezers are designed for the purpose of holding pre-frozen bulk
product and although they are capable of freezing small quantities of non-frozen
product, they are not to be used as fast or blast freezers. Do not attempt to freeze
bulk quantities of product. The temperature control is accessible from the top of
the electrical console box located on the cabinet top behind the front grill (see
figure 6).if an adjustment is necessary to maintain the above temperature range
only on standard freezers, place a screwdriver into the thermostat slot and turn
clockwise for a colder cabinet temperature or counterclockwise for a warmer

- 14 -

Advertising