Cabletron Systems FRX6000 User Manual

Page 78

Advertising
background image

Configuring the Trap Table

3-28

Trap Messages

SDLC No CTS on link

721

A necessary CTS was not received from the DCE.

Severity

Major (Level 2)

Action

Check the modem to make sure it is operational.

SDLC No External Clock

722

The necessary clock is not being provided.

Severity

Major (Level 2)

Action

Check the modem to make sure it is operational.

SDLC LLC/2 Remote Link Stn lost

736

The remote station is not responding. Either the Inactivity Timer (Ti) or
Acknowledgment Timer (T2) has expired.

Severity

Major (Level 2)

Action

Check the remote station to make sure it is operational.

LLC/2 DM Received

737

The remote station sent a Disconnect Mode response and the logical link is down.

Severity

Major (Level 2)

LLC/2 SABME Received when open

738

The remote station sent a SABME to the local station, but the local station had
already been initialized via a SABMEÑUA exchange.

Severity

Major (Level 2)

Action

None; however, if the problem persists, contact your support
representative.

LLC/2 FRMR Rcvd, Invalid Command

739

The remote device received an invalid or unsupported command, and returned a
Frame Reject.

Severity

Major (Level 2)

LLC/2 FRMR Rcvd, IFLD not permitted

740

The remote device received an I-frame when it was not permitted, and returned a
Frame Reject.

Severity

Major (Level 2)

LLC/2 FRMR Rcvd, Invalid Nr

741

The remote device received an invalid N

(R),

and returned a Frame Reject.

Severity

Major (Level 2)

Advertising
This manual is related to the following products: