Gfa-7400, Gfa-7300 – Adcom GFA-7300 User Manual

Page 10

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

o

12VDC Triggering. (GFA-7400 Only)

The GFA-7400 and GFA-7300 are very high power amplifiers and as such must be directly

connected to the wall outlet or an appropriate surge protector or AC line conditioner. It must never
be connected to the “switched” outlets on the rear panel of a pre-amplifier. Usually this would
mean that when you turn on/off your pre-amplifier you would have to turn on/off your power
amplifier separately. We have however provided the ability to control the OFF/ON function of the
GFA-7400 by a 12Volt DC output jack on the rear of certain ADCOM pre-amplifiers and tuner pre­
amplifiers. When using this feature the front panel Power Switch must be left in the in “on”

position. To connect you will need a monaural mini phone plug to monaural mini phone plug cable

of appropriate length (not included) to reach from the rear panel of the amplifier to the rear panel
of the pre-amplifier. Contact your dealer for information on using this feature with ADCOM and
other brand pre-amplifiers. Although 12VDC is optimal the circuit will operate from approx. 5 to
30VDC, not to exceed 250mv. Center conductor (tip) is positive (+).

O

AC Fuse

The AC Fuse protects the electronic circuits of the GFA-7400/7300. This fuse, normally, will

fail only if there is an overload within the GFA-7400/7300. It may, however, fail if the amplifier
attempts to deliver very high power into very low-impedance loudspeakers. In either case, BE
SURE TO REPLACE THE AC Fuse ONLY WITH AN EXACT REPLACEMENT FUSE. The proper
fuse values are:

GFA-7400:

Fuse Rating

BUSS®

Littelfuse®

For 115 volt operation.......15 Amp 250 Volt..... ...... ABC-15/250V........(3AB)314015/250V
For 230 volt operation....

.... 8 Amp 250 Volt............ AGC-8/250V..... ....(3AG)312008/250V

GFA-7300:

Fuse Ratina

BUSS®

Littelfuse®

For 115 volt operation....

,...T8 Amp 250 Volt..... ...... MDL-8A/250V........(3AG) 313008/250V

For 230 volt operation....

....T4Amp 250 Volt............ MDL-4A/250V........(3AG)313004/250V

WARNING

Before attempting to replace a failed fuse, be certain to unplug the AC Power Cord from the AC

wall outlet to prevent possible electrical shock.

Replace the AC Fuse on/y with one identical in type and rating as printed on the rear panel. DO
NOT USE ANY SUBSTITUTE FUSES WITH DIFFERENT RATINGS OR VALUES. Failure to

observe this precaution may cause serious damage to the amplifier circuits, MAY CREATE A

FIRE HAZARD, AND MAY VOID THE WARRANTY.

If the Power LED

(

0

)

does not glow, it may be an indication that the AC fuse has blown. If

you are using the 12VDC Triggering feature (GFA-7400 Only) it may be possible that there is a

problem with that connection. To determine if the problem is caused by a malfunction in the

12VDC system, remove the small plug inserted into the 12VDC Triggering jack. Press the front

panel power switch to turn off the amp, and immediately re-press the power switch. If the problem
is caused by the 12VDC triggering circuit the amp will turn on and the LED will glow. DO NOT

attempt repair of the 12VDC system. If you are not sure, or the amplifier displays other symptoms,

please consult the RESOLVING PROBLEMS section on page 13.

10

Advertising
This manual is related to the following products: