Maintenance – Craftsman 919.166442 User Manual

Page 15

Advertising
background image

15 - ENG

A13640

MAINTENANCE

Customer Responsibilities

Daily
or after
each
use

Before
each
use

Check Safety Valve

Drain Tank

NOTE: See Operation section for the
location of controls.

To Drain Tank

1. Set the On/Auto/Off lever to

"Off".

2. Turn the regulator knob counter-

clockwise to set the outlet
pressure to zero.

3. Remove the air tool or accessory.

4. Pull ring on safety valve allowing

air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.

5. Drain water from air tank by

opening drain valve (counter-
clockwise.

Risk of Bursting.
Water will

condense in the air tank. If not
drained, water will corrode and
weaken the air tank causing a risk
of air tank rupture.

6. After the water has been drained,

close the drain valve (clockwise).
The air compressor can now be
stored

NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, the
reinstalled.

To Check Safety Valve

Risk of Bursting.
If the safety valve

does not work properly, over-
pressurization may occur, causing
air tank rupture or an explosion.

1. Before starting compressor, pull

the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve
is stuck or does not operate
smoothly, it must be replaced
with the same type of valve.

Risk of Unsafe
Operation. Unit

cycles automatically when power
is on. When servicing, you may
be exposed to voltage sources,
compressed air, or moving parts.
Before servicing unit unplug or
disconnect electrical supply to
the air compressor, bleed tank
of pressure, and allow the air
compressor to cool.

Advertising