DETAILED COOLING CAPACITIES*

Evaporator

CONDENSER ENTERING AIR TEMPERATURES °F

Air

85

95

105

115

E

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

CFM

W

MBtuhf

System

MBtuhf

System

MBtuhf

System

MBtuhf

System

B

Total

Senst

KW**

Total

Sensf

KW**

Total

Sensf

KW**

Total

Sensf

KW**

544B060 Outdoor Section With 517E/GN063 Indoor Section

72

62.2

31.0

6.38

59.3

30.0

6.82

56.0

28.9

7.25

52.5

27.7

7.64

1900

67

57.0

40.1

6.23

53.8

38.9

6.64

50.5

37.6

7.01

47.3

36.4

7.36

62

51.7

48.7

6.07

48.9

47.3

6.44

46.1

45.7

6.79

43.5

43.5

7.14

57

50.6

50.6

6.04

48.3

48.3

6.41

45.9

45.9

6.78

43.5

43.5

7.14

72

62.7

31.9

6.50

59.9

31.0

6.95

56.6

30.0

7.38

53.0

28.8

7.78

2100

67

57.7

42.0

6.36

54.5

40.9

6.77

51.1

39.6

7.15

47.7

38.3

7.50

62

52.7

51.3

6.21

49.8

49.6

6.58

47.2

47.2

6.96

44.7

44.7

7.32

57

52.2

52.2

6.20

49.7

49.7

6.58

47.2

47.2

6.96

44.7

44.7

7.32

72

63.0

32.7

6.61

60.3

32.0

7.07

57.0

31.0

7.50

53.3

29.9

7.91

2300

67

58.2

43.8

6.48

55.0

42.8

6.90

51.5

41.5

7.28

48.1

40.1

7.63

62

53.6

53.4

6.35

50.9

50.9

6.74

48.3

48.3

7.12

45.7

45.7

7.49

57

53.4

53.4

6.35

50.9

50.9

6.74

48.3

48.3

7.12

45.7

45.7

7.49

Multipliers for Determining the Performance With Other Indoor Sections

Indoor

Section

Size

Cooling

Indoor

Section

Size

Cooling

Capacity

Power

Capacity

Power

506 B

060

0.94

0.93

509A/519D

057C

0.95

0.94

061

1.00

0.95

060

0.97

0.94

517E/G

060

0.96

1.01

061

1.00

0.95

062

0.97

0.98

519C

060

0.93

0.90

063

1.00

1.00

*Detailed cooling capacities are based on indoor and outdoor unit at the same elevation and connected by 25 feet of tubing. If other than 25

feet of tubing is used and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.

tTotal and sensible capacities are net capacities. Blower motor heat has been subtracted.
:|;Sensible capacities shown are based on 80°F entering air at the indoor coil. For sensible capacities at other than 80°F, deduct 835 Btuh per

1000 Cfm of indoor coil air for each degree below80°F, or add 835 Btuh per 1000 Cfm of indoor coil air per degree above 80°F.

**Unit KW is total of indoor and outdoor unit KW’s.

HEAT PUMP HEATING PERFORMANCE

544B018/

517EN024

Indoor Coil Airflow

Cfm* 675

EDB*

70°

OUTDOOR COIL ENTERING AIR TEMPERATURE °F

-3

7

17

27

37

47

57

67

Instaneous Capacity (MBtuh)

6.21

8.29

10.6

13.1

15.9

19.0

22.6

26.5

Integrated Capacity (MBtuh)f

5.72

7.61

9.66

11.7

14.5

19.0

22.6

26.5

Total Power Input (KW)f

1.34

1.44

1.55

1.67

1.80

1.94

2.12

2.33

Multipliers for Determining the Performance With Other Indoor Sections

Indoor

Section

Size

Heating

Indoor

Section

Size

Heating

Capacity

Power

Capacity

Power

508A

024

0.98

0.99

517E

018

0.98

1.01

510B

024

0.99

0.98

024

1.00

1.00

513C

018

0.95

1.00

519D/509A

018

0.96

1.01

024

0.97

0.97

024

0.98

0.99

516A

018

0.98

1.00

024

0.99

0.99

544B024/

517EN030

Indoor Coil Airflow

Cfm* 900

EDB*

70°

OUTDOOR COIL ENTERING AIR TEMPERATURE °F

-3

7

17

27

37

47

57

67

Instantaneous Capacity (MBtuh)

9.85

12.3

19.9

17.9

21.4

25.4

30.5

36.0

Integrated Capacity (MBtuh)f

9.06

11.3

13.6

15.9

19.5

25.4

30.5

36.0

Total Power Input (KW)f

2.01

2.13

2.24

2.35

2.48

2.61

2.79

3.00

Multipliers for Determining the Performance With Other Indoor Sections

Indoor

Section

Size

Heating

Indoor

Section

Size

Heating

Capacity

Power

Capacity

Power

506B

030

0.98

0.98

517E

024

1.00

1.00

036

0.97

0.94

030

1.00

1.00

508A

024

0.99

1.01

036

1.00

1.00

513C

024

0.98

0.99

519D/509A

024

0.98

0.98

030

1.00

1.00

030

0.99

0.99

030X

0.99

0.99

*See the Heating Performance Correction Factors Table for Cfm and indoor coil entering air temperature adjustments.
tThe Btuh heating capacity values shown are net “integrated” values from which the defrost effect has been subtracted. The Btuh heating from sup­

plement heaters should be added to those values to obtain total system capacity.

tThe KW values include the compressor, outdoor fan motor, and indoor blower motor. The KW from supplement heaters should be added to these val­

ues to obtain total system KW.

HP-60