Troubleshooting, F01 — internal shorted cell battery, F03 — sulfate or unchargeable battery – Black & Decker VEC1093DBD User Manual

Page 8: F04 — overtime condition, Fob — overheated condition, Fob — reverse polarity, F07 — alternator voltage, Charging a very cold battery

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

TROUBLESHOOTING

Display Indfcations/Common Problems/Possible Solutions

No Functions

• Check and make sure the charger is plugged into a live 110/1 20 volt AC outlet.

• Follow the steps outlined in the Operating Instructions section.

F01Internal Shorted Cell Battery

If the battery being charged has an internal shorted cell, the F01 will show. We
recommend taking your battery to a certified automotive service center for evaluation.

F02

Bad Battery Connection or Battery Voltage Too Low to Accept

Charge

When F02 appears, the most common cause is poor connection to battery.

" Follow the steps outlined in "Important Safety Instructions" at the front of this manual

to disconnect AC cord and clamps, clean battery terminal and reconnect.

• If the situation persists, we recommend taking your battery to a certified automotive

service center for evaluation.

F03Sulfate or Unchargeable Battery

Appears when the battery is highly sulfated and cannot accept normal charge current.

" Follow the steps in "Recondition Mode" to recondition the battery.

• Follow the steps in "Fgualizing" to equalize the battery.

" If the situation persists after reconditioning and eciualizing, we recommend taking

your battery to a certified automotive service center for evaluation,

F04Overtime Condition

Appears when charging time exceeds 18 hours. You may be using a charge current
rate too low for a large battery. Select higher charge rate to charge the battery.

FOB

Overheated Condition

The ventilation grill that prevents the air from flowing in and out of the charger may

be blocked.

• Follow the steps outlined in "Important Safety Instrtjctions" at the front of tills manual to

disconnect AC cord and clamps, allow tlie unit to cool for 30 minutes and reconnect.

• Make sure there is ample ventilation before resuming operation,

FOBReverse Polarity

The connections to the battery's POSITIVE and NEGATIVE terminals are incorrect.

Follow the steps outlined in "Important Safety Instructions" at the front of this manual

to disconnect AC cord and clamps and reconnect to battery with correct polarity.

F07Alternator Voltage

Alternator output voltage is out of typical operation range,

Charging a Very Cold Battery

If the battery to be charged is very cold (in temperatures below freezing — 0"C/ 32°F),
it cannot accept a high rale of charge. The initial charge rate will be low. The charge
rate will increase as the battery warms. Never attempt to cliarge a frozen battery.

10

Advertising