4.B POSSIBLE EMERGENCIES AND

RECOMMENDED ACTIONS

A WARNING

If gas or electricity is off due to an

emergency, only a qualified installer, service
agency or gas supplier should turn it back on.
Doing it yourself could result in damage, Injury
or death.

1. Possible Emergency: Smelling gas or other

unfamiliar smell; or not knowing what may be wrong

or that to do about it.

ACTION: For your safety -

a. Leave your house or building immediately.

b. Go to a neighbor’s or another building.

c. Use their telephone.

d. Call your gas supplier. Tell them you smell gas

and give them your name and address.

e. If you cannot reach gas supplier, call fire

department.

A

WARNING

Three important things not to do -

1. Don’t try to light any gas appliances.

2. Don’t touch any electrical switches
3. Don’t use the telephone in your house or

building.

Any of the above may cause a spark which

could cause a fire or explosion resulting in

damage, personal injury or death.

2. Possible Emergency: Your therTnostat is set below

room temperature; yet even though the blower is on,

the air coming from your room registers continually
gets hotter.

ACTION:

a. Turn room thermostat to its lowest or OFF

setting,

b. If you can do so safely, turn gas off. Use manual

shutoff valve at gas meter or on propane (LP) gas
lank. You may need a wrench or tools. If you
can safely turn off electricity at the main circuit

circuit panel, do so. If you cannot do these things

safely, leave your home or building immediately.

Call your gas supplier or fire department from a

neighbor’s phone for help.

c. Your furnace should now be off. If it is. call your

service technician or gas supplier,

d. If your furnace continuers to run, leave your

home or building immediately. Call your gas
supplier or fire department from a neighbor's

phone for help.

3. Possible Emergency : Your thermostat is set above

room temperature. The blower is on but the air
coming from your room registers is hot, then cold,
then hot, then cold in a continuing cycle. This
condition indicates lack of airflow through furnace.

ACTION:

a. Make sure air filter is clean and installed

correctly.

b. Check that registers and return air grilles are

open and unobstructed.

c. If condition continues, call your local qualified

service technician or gas supplier.

4. Possible Emergency: While furnace is operating,

you smell unfamiliar odors that go away when

furnace is off.

A

WARNING

Unfamiliar odors may mean gas or aldehydes

are present which could result in damage, injury

or death.

ACTION:

a. Tlim thennostat to its lowest or OFF setting.

b. Move gas valve control level to OFF.

c. If blower is not operating, immediately turn of

electricity to furnace using shutoff device near
furnace or at main circuit panel.

d. If blower is operating, wait five minutes for

furnace to cool down and then turn off electricity
to furnace using shutoff device near furnace or at
main circuit panel.

e. Call your local qualified service technician or gas

supplier,

5. Possible Emergency: Main electrical circuit breaker

for furnace cannot be reset without tripping again or

new fuses continue to blow.

ACTION:

a. Move gas valve control level to OFF.

b. Call your local qualified service technician or gas

supplier.