I. Upon completion of installation

nothing works.

Check if unit has been plugged in, make sure that all power has been
turned back on and all electrical wiring are properly connected.

2. Light is on but blower is not

turning at all or seems to be
scraping on something.

Blower blade unit might have been mounted too low and scraping

the bottom or jammed. Loosen hex screw on blade unit and adjust to

proper height.

3. When blower is on,

something seems to be loose
and spinning around inside.

There might have been foreign particles left within the discharge

opening or rocks, leaves, branches, etc. that might have fell in from
old duct work. Disconnect duct work to inspect and remove any
foreign particles.

4. Vibration when blower is on

Unit might not have been secured properly on cabinet. Or cabinet
might need to be further secured into studs on wall.

5. Blower noise

Our blowers are designed to perform up to 280 cfm. A properly
functioning motor itself should be relatively quiet. Nevertheless, due
to vacuum created by the suction, noise level up to 4 sones will be
generated when blower unit is turned on at its maximum speed.
Employing low speeds will suffice moderate cooking such as steam­
ing, broiling etc.

6. Light is not working

Light bulb might need to be replaced. On some instances, the fragile
bulb could have been damaged during the shipping process.
Replace light bulb.

7. Blower seems \A/eak

Check duct size used, duct size should be at least 3 1/4" x lO".
Range hood WILL NOT function properly with the insufficient
duct size.
Check if duct is clogged or if dumper unit is not opening properly. A
tight mesh on a side wall cap unit might also cause restriction to the
air flow.
Use a damper type sidewall cap.
Reduce the number of elbows and length of duct work or increase
duct size.
Check if all joints are properly connected, sealed and taped.

8. Cooking fumes and smoke

dissipates before it reaches
the blower.

Check if unit is installed at the recommended height. The range hood
should also be able to cover the entire cooking area from left to right
and most areas from rear to front.
Open doors and windows might also distract air flow before it reach­
es the blower.
Make sure blowers are on high speed for heavy cooking.